Gate operator setup examples

The following are example setups for the gate operator. Your specific site requirements may be different. Always setup the operator system to the site
requirements, including all necessary entrapment protection devices.
RESIDENTIAL: One to four residential homes sharing a gated entrance/exit, allowing vehicle access trumps security concerns
COMMERCIAL/GENERAL ACCESS: A residential community (more than four homes) having one or more gated entrances/exits, allowing vehicle access
trumps security concerns
COMMERCIAL: Business site where security (gate closed) is important
INDUSTRIAL: Large business site where security is required
SETTING
RESIDENTIAL
Quick Close switch
Normally set to OFF. Normal gate
setting
close (timer or control).
Anti-Tail switch setting
Normally set to OFF. CLOSE
EYES/Interrupt loop reverses a
closing gate.
Bipart Delay switch
For DUAL-GATE site, set to ON for
setting
gate that delays upon opening.
Aux Relay Out – Open
Typically not required.
Limit Switch
Aux Relay Out – Close
Typically not required.
Limit Switch
Aux Relay Out – Gate
Attach alert signal (audible or
Motion
visual alert system).
Aux Relay Out – Pre-
Attach alert signal (audible or
Motion Delay
visual alert system).
Attach alert signal (audible or
Aux Relay Out – Tamper
visual alert system) to indicate if
(Slide Gates Only)
gate is manually tampered with by
being pushed off of close limit.
Cycle Quantity Feedback Use during servicing only to
determine operator cycles.
Fire Dept Open Input
Typically not required.
Heater Accessory
The heater keeps the gearbox and
(Models HTRNB and
batteries at a suitable temperature
HTR460)
when the outside temperature is
below -4°F. The thermostat MUST
be set between 45°F and 60°F to
ensure proper gate operation.

SETTINGS

COMMERCIAL/GENERAL
ACCESS
Normally set to OFF. Normal gate
close (timer or control).
Normally set to OFF. CLOSE
EYES/Interrupt loop reverses a
closing gate.
For DUAL-GATE site, set to ON for
gate that delays upon opening.
Use with SAMS (Sequence Access
Management System).
Typically not required.
Attach alert signal (audible or
visual alert system).
Attach alert signal (audible or
visual alert system).
Attach alert signal (audible or
visual alert system) to indicate if
gate is manually tampered with by
being pushed off of close limit.
Use during servicing only to
determine operator cycles.
Connect emergency access
system (Knox box switch, SOS
system, etc.).
The heater keeps the gearbox and
batteries at a suitable temperature
when the outside temperature is
below -4°F. The thermostat MUST
be set between 45°F and 60°F to
ensure proper gate operation.
36
COMMERCIAL
Normally set to OFF. Normal gate
close (timer or control).
Set to ON. In attempt to prevent
vehicle tail-gating, CLOSE EYES/
Interrupt loop pauses a closing
gate.
For DUAL-GATE site, set to ON for
gate that delays upon opening.
1. Use with SAMS (Sequence
Access Management
System).
2. Connect "Gate Open"
indicator (e.g. light).
Connect "Gate Close/Secure"
indicator (e.g. light).
Attach alert signal (audible or
visual alert system).
Attach alert signal (audible or
visual alert system).
Attach alert signal (audible or
visual alert system) to indicate if
gate is manually tampered with by
being pushed off of close limit.
Use during servicing only to
determine operator cycles.
Typically not required.
The heater keeps the gearbox and
batteries at a suitable temperature
when the outside temperature is
below -4°F. The thermostat MUST
be set between 45°F and 60°F to
ensure proper gate operation.
INDUSTRIAL
Set to ON, so that gate closes
immediately after vehicle passes
CLOSE EYES/Interrupt loop.
Set to ON. In attempt to prevent
vehicle tail-gating, CLOSE EYES/
Interrupt loop pauses a closing
gate.
For DUAL-GATE site, set to ON for
gate that delays upon opening.
1. Use with SAMS (Sequence
Access Management
System).
2. Connect "Gate Open"
indicator (e.g. light).
Connect "Gate Close/Secure"
indicator (e.g. light).
Attach alert signal (audible or
visual alert system).
Attach alert signal (audible or
visual alert system).
Attach alert signal (audible or
visual alert system) to indicate if
gate is manually tampered with by
being pushed off of close limit.
Use during servicing only to
determine operator cycles.
Typically not required.
The heater keeps the gearbox and
batteries at a suitable temperature
when the outside temperature is
below -4°F. The thermostat MUST
be set between 45°F and 60°F to
ensure proper gate operation.