Power Wiring - Chamberlain LiftMaster CSL24V Installation Manual

Vehicular slide gate operator elite series
Hide thumbs Also See for LiftMaster CSL24V:
Table of Contents

Advertisement

WIRING

POWER WIRING

This operator can be wired for either 120 Vac or 240 Vac or a solar
panel (not provided). Follow the directions according to your application.
For dual gate applications, power will have to be connected to each
operator. Main power supply and control wiring MUST be run in
separate conduits.
NOTE: If using an external receiver use shielded wire for the connections and
mount the receiver away from the operator to avoid interference with the operator.
AMERICAN WIRE
MAXIMUM WIRE
GAUGE (AWG)
LENGTH (120 VAC)
14
12
10
8
6
4
NOTE: Use copper conductors ONLY.
AC POWER SWITCH
The AC Power switch on the operator will turn the incoming 120/240 Vac power ON
or OFF. The operator's AC Power switch ONLY turns off AC power to the control board
and DOES NOT turn off battery power.
240 VAC ONLY
If using the 240 Vac option a heater cannot be used. The accessory outlet is disabled
and cannot be used with the 240 Vac option.
1
Remove the outlet housing from the electrical box by removing the screws (2).
2
Pull the outlet housing out and locate the power wiring connector on the EMI
board.
3
Unplug the power wiring connector from the 120 Vac socket (factory default
location) and plug it into the 240 Vac socket.
4
Replace the outlet housing by securing with the screws. The operator is now set
for 240 Vac operation.
MAXIMUM WIRE
LENGTH (240 VAC)
130 feet
260 feet
205 feet
410 feet
325 feet
650 feet
520 feet
1040 feet
825 feet
1650 feet
1312 feet
2624 feet
NUMBER OF CYCLES PER DAY
Slide Gate Installation (16 ft. 1000 lb. gate)
Accessory
Current Draw
TRANSFORMER
POWERED
BATTERY
POWERED
AC Power Switch
Outlet Housing
EMI Board
240 Vac Socket
15
POWER WIRING
Single Gate
7AH Batteries
33AH Batteries
(standard)
Continuous
Continuous
Continuous
Continuous
100
45
45
40
Power Wiring Connector
(120 Vac Socket, factory default)
(optional)
Continuous
Continuous
Continuous
Continuous
275
270
270
260