Chamberlain CSL24V Manual
Chamberlain CSL24V Manual

Chamberlain CSL24V Manual

Solar gate access system daily cycle chart manual
Hide thumbs Also See for CSL24V:

Advertisement

CSW24V & CSL24V

SOLar gaTE aCCESS SYSTEM DaiLY CYCLE CHarT

The CSW24V and CSL24V Solar Gate Access System
utilizes an innovative Power Management System to
LA412 Solar Gate Access System Daily Cycle Chart
deliver power when needed most for operating a gate
while minimizing power consumption at all other times.
The LA412 Solar Gate Access System utilizes the innovative EverCharge
Power is provided to the gate operator via batteries.
when needed most for operating a gate while minimizing power consumption at all other times. Power is provided to the
The batteries are charged from a solar panel(s)
gate operator via batteries. The batteries are charged from a solar panel(s) connected to the operator control board. The
connected to the operator control board. The number
number of solar panels required is determined by whether the application is for a single or dual gate, daily cycle rate,
of solar panels required is determined by whether the
number of accessories and region of the country.
application is for a single or dual gate, daily cycle rate,
The map and daily cycle rate shown are approximations based upon the average solar radiation and the temperature
number of accessories and region of the country.
effects on batteries in the given regions. Local geography and weather conditions may require additional solar panels.
The map and daily cycle rate shown are
Low power draw or Wireless Accessories are recommended in order to minimize power draw, as added accessories draw
approximations based upon the average solar radiation
power and affect the daily cycle rate.
and the temperature effects on batteries in the given
Solar panel(s) must be located in an open area clear of obstructions and shading for the entire day. Snow, heavy fog or
regions. Local geography and weather conditions
heavy rain affect solar panel performance and charge rate. The LA412 is not supported in climates where temperatures
may require additional solar panels. Low Power Draw
reach below -4°F. This is due to the affect of cold weather on batteries and a reduced number of hours of sunlight during
or Wireless Accessories are recommended in order
the winter months. Cycle rate may vary from solar chart for areas that reach below 32°F. Optional external power reserve
to minimize power draw, as added accessories draw
model BIGBTYKIT (80Ah battery not included) or extra large control box model LA412CONTXLM (with 33Ah battery)
power and affect the daily cycle rate.
recommended for applications that reach below 32°F (and above -4°F) for more than 2 consecutive weeks during the
winter months. Solar panels should be cleaned regularly to ensure proper operation.
Not Available
4
To place your order or for more information, visit dealer.liftmaster.com
10
or contact your Sales or Customer Care Representative at 800.323.2276.
3
1
1
NUMBER OF CYCLES PER DAY (SOLAR)
Slide Gate
CONFIGURATION
Installation (16 ft.
1000 lb. gate)
or
Swing Gate
installation
(800lbs 12ft Gate)
40W SOLAR PANEL
NOTE: 40W would be two 20W
panels in series.
per operator
Solar panel(s) must be located in an open area clear
of obstructions and shading for the entire day. Snow,
heavy fog or heavy rain affect solar panel performance
and charge rate. The CSW24V and CSL24V is not
Power Management System to deliver power
®
supported in climates where temperatures reach
below -4°F. This is due to the effect of cold weather on
batteries and a reduced number of hours of sunlight
during the winter months. Cycle rate may vary from
solar chart for areas that reach below 32°F. Optional
33Ah batteries (2) recommended for applications that
reach below 32°F (and above -4°F) for more than
2 consecutive weeks during the winter months.
Solar panels should be cleaned regularly to ensure
proper operation.
For solar applications disconnect the expansion
board and do not use the wireless dual gate feature.
These features will substantially decrease the cycle
rate and standby time.
4
3
Not Available
2
ZONE 1
ZONE 2
ZONE 3
(6 Hrs
(4 Hrs
(2 Hrs
sunlight/day)
sunlight/day)
sunlight/day)
70
92
31
90
100
69
90
30
88
100
59
80
20
79
100
4
1
39
38
28

Advertisement