CONNECT BATTERIES

7AH BATTERIES
The batteries are charged in the circuit by the integrated transformer. The batteries
are for battery backup or solar installation.
1
Turn OFF AC power to the operator.
2
Unplug the J15 plug labeled BATT on the control board by squeezing the plug
and pulling it from the control board. This disconnects the ac/dc power to the
the control board.
3
Connect a jumper between the positive (+) terminal of one battery to the
negative terminal (-) of the other battery.
4
Connect the red wire from the J15 plug to the positive (+) terminal of the
battery.
5
Connect the black wire from the J15 plug to the negative (-) terminal of the
battery.
6
Plug the J15 plug back into the control board. This will power up the control
board. NOTE: You may see a small spark when plugging the J15 plug into the
board.
7
Turn ON AC power to the operator.
8
Turn ON the AC power switch on the operator.
Model CSL24VH (with heater) set