CSL24V™& CSL24VH™ VEHICULAR SLIDE GATE OPERATOR I N S T A L L A T I O N M A N U A L Your model may look different than the model illustrated in this manual. THIS PRODUCT IS TO BE...
SAFETY UL325 MODEL CLASSIFICATIONS UL325 MODEL CLASSIFICATIONS CLASS I – RESIDENTIAL VEHICULAR GATE OPERATOR A vehicular gate operator (or system) intended for use in a home of one-to four single family dwellings, or a garage or parking area associated therewith. CLASS II –...
SAFETY SAFETY INSTALLATION INFORMATION SAFETY INSTALLATION INFORMATION 1. Vehicular gate systems provide convenience and security. Gate systems are 8. Controls intended for user activation must be located at least 6 feet (1.8 m) comprised of many component parts. The gate operator is only one away from any moving part of the gate and where the user is prevented component.
SAFETY GATE CONSTRUCTION INFORMATION GATE CONSTRUCTION INFORMATION Vehicular gates should be installed in accordance with ASTM F2200: Standard Specification for Automated Vehicular Gate Construction. For a copy, contact ASTM directly at 610-832-9585 or www.astm.org. GENERAL REQUIREMENTS 3.1.3 A gap, measured in the horizontal plane parallel to the roadway, between a fixed stationary object nearest the roadway, (such as a gate support post) Gates shall be constructed in accordance with the provisions given for the and the gate frame when the gate is in either the fully open position or the...
SAFETY REQUIRED ENTRAPMENT PROTECTION DEVICES REQUIRED ENTRAPMENT PROTECTION DEVICES To prevent SERIOUS INJURY or DEATH from a moving gate: • Entrapment protection devices MUST be installed to protect anyone who may • Locate entrapment protection devices to protect between moving gate and come near a moving gate.
SAFETY IMPORTANT SAFETY INFORMATION IMPORTANT SAFETY INFORMATION INSTALLATION To prevent SERIOUS INJURY or DEATH from a moving gate: • Pinch points must be guarded at all times. Install enclosed-style gate tracks and • Entrapment protection devices MUST be installed to protect anyone who may roller guards.
• To reduce the risk of FIRE or INJURY to persons use ONLY LiftMaster part • ALWAYS keep people and objects away from the gate. NO ONE SHOULD CROSS 29-NP712 for replacement batteries.
INTRODUCTION FEATURES FEATURES OPERATOR FEATURES • Advanced "Centerpiece" Control Board • Manual - Secure power failure selection • AC Surge Protection and EMI Filter Board • SAMS compatible - Main AC voltage input selection: 120 Vac (factory setting) or • Slow-start and slow-stop gate motion 240 Vac (field change) •...
PREPARATION SITE PREPARATION Check the national and local building codes BEFORE installation. GATE Gate must be constructed and installed according to ASTM F2200 standards (refer to page 4). Gate must fit specifications of operator (refer to specifications). SAFETY CATCH ROLLERS DO NOT use a gate catch post.
SITE PREPARATION CONDUIT & CONCRETE PAD EARTH GROUND ROD Conduit must be UL approved for low and high voltage. Consider the operator Proper grounding gives an electrical placement BEFORE installing the pad or post. charge, such as from an electrical static discharge or a near lightning strike, a path from which to dissipate its energy safely into the earth.
INSTALLATION DETERMINE LOCATION FOR CONCRETE PAD AND OPERATOR + CONCRETE PAD & OPERATOR ATTACHMENT DETERMINE LOCATION FOR CONCRETE PAD AND OPERATOR STANDARD INSTALLATION The gate operator should be installed near the front roller of the gate or near the back of the gate (in the OPEN position). The space between the gate and the output sprocket must be a minimum of 4 inches.
INSTALLATION STANDARD INSTALLATION ONLY + REAR INSTALLATION ONLY STANDARD INSTALLATION ONLY DO NOT run the operator until instructed. Manually open the gate and line up the front bracket so the chain will be level with the idler pulley and parallel to the ground. Weld the front bracket in this position.
WIRING WIRE THE ENTRAPMENT PROTECTION DEVICES + EARTH GROUND ROD WIRE THE ENTRAPMENT PROTECTION DEVICES Entrapment protection devices are required. Refer to page 5 for more information regarding application. To prevent SERIOUS INJURY or DEATH from a moving gate: • Entrapment protection devices MUST be installed to protect anyone who may •...
WIRING POWER WIRING POWER WIRING This operator can be wired for either 120 Vac or 240 Vac or a solar AMERICAN WIRE MAXIMUM WIRE MAXIMUM WIRE panel (not provided). Follow the directions according to your application. GAUGE (AWG) LENGTH (120 VAC) LENGTH (240 VAC) For dual gate applications, power will have to be connected to each 130 feet...
For solar applications DO NOT use the expansion board and the wireless dual gate feature. These features will substantially decrease the cycle NOT AVAILABLE rate and standby time of the operator. We recommend LiftMaster low power NOT AVAILABLE draw accessories to minimize power draw, refer to accessory page.
The batteries are charged in the circuit by the integrated transformer. The batteries Jumper Black Wire are for battery backup. Model CSL24VH (with heater) set Turn OFF AC power to the operator. batteries in tray below the heater. Unplug the J15 plug labeled BATT on the control board by squeezing the plug and pulling it from the control board.
WIRING CONNECT BATTERIES CONNECT BATTERIES CONTINUED... 33AH BATTERIES The batteries are charged in the circuit by the integrated transformer. The batteries (without heater) are for battery backup or solar installation. The 33AH application requires the 33AH wire harness (Model K94-36596). NOTE: If 33AH batteries (2) are used, the battery tray underneath the heater will need to be removed to allow more space in the enclosure (if applicable).
WIRING DUAL GATES ONLY DUAL GATES ONLY There are two options for dual gate communication: wired or wireless. Follow the directions according to your application. Do not use wired and wireless communication simultaneously. Wired dual gate applications will have a longer battery standby time than wireless applications. WIRELESS DUAL GATES TO ACTIVATE THE WIRELESS FEATURE: Choose an operator to be the network primary operator.
WIRING DUAL GATES ONLY DUAL GATES ONLY CONTINUED... WIRED DUAL GATES Before digging, contact local underground utility locating companies. Use PVC conduit to prevent damage to cables. Disconnect ALL power to the operator and unplug the J15 plug from DUAL GATE WIRE TYPE (SHIELDED TWISTED PAIR CABLE) the control board.
ADJUSTMENT LIMIT AND FORCE ADJUSTMENT LIMIT AND FORCE ADJUSTMENT To reduce the risk of SEVERE INJURY or DEATH: • Without a properly installed safety reversal system, persons (particularly small • NEVER use force adjustments to compensate for a binding or sticking gate. children) could be SERIOUSLY INJURED or KILLED by a moving gate.
ADJUSTMENT LIMIT AND FORCE ADJUSTMENT + OBSTRUCTION TEST FINE TUNE THE FORCE The FORCE DIAL on the control board is used for fine tuning the force in cases where wind or environmental changes may affect the gate travel. Based on the length and weight of the gate it may be necessary to make additional force adjustments.
PROGRAMMING REMOTE CONTROLS + ERASE ALL CODES REMOTE CONTROLS (NOT PROVIDED) A total of 50 Security✚ 2.0™ remote controls and 2 keyless entries (1 PIN for each keyless entry) can be programmed to the operator. When programming a third keyless entry to the operator, the first keyless entry will be erased to allow the third keyless entry to be programmed.
FINISH INSTALLATION INSTALL THE COVER INSTALL THE COVER The operator cover consists of two pieces: a rear cover and a front cover. The front cover can easily be removed to access the electrical box. To access the reset switch slide the access door up.
OPERATION RESET SWITCH + MANUAL DISCONNECT + OPERATOR ALARM + REMOTE CONTROL + HEATER (IF APPLICABLE) RESET SWITCH The reset switch is located on the front of the operator and serves several functions. NORMAL OPERATION Toggling the reset switch will stop a moving gate during a normal open/close cycle, like a stop button.
ADDITIONAL FEATURES CONTROL BOARD OVERVIEW CONTROL BOARD OVERVIEW The SET OPEN button sets the OPEN limit. See Adjust Limits section. SET OPEN Button: The SET CLOSE button sets the CLOSE limit. See Adjust Limits section. SET CLOSE Button: The MOVE GATE buttons will either open or close the gate when the operator is in Limit setting mode. See Adjust Limits section. MOVE GATE Buttons: The LOCK/BIPART DELAY switch is used only for dual gates.
ADDITIONAL FEATURES WIRING ACCESSORIES TO THE CONTROL BOARD WIRING ACCESSORIES TO THE CONTROL BOARD Refer to the chart below and the corresponding image for a description of the control (right side of control board) board inputs. Open Open Input (& Open command - opens a closed gate.
ADDITIONAL FEATURES EXPANSION BOARD OVERVIEW EXPANSION BOARD OVERVIEW QUICK CLOSE Switch: OFF: No change to the gate's normal operation. To AVOID damaging the circuit board, relays or accessories, DO NOT connect ON: When CLOSE EYES/Interrupt loop is deactivated it causes an opening or a stopped more than 42 Vdc (32 Vac) to the AUX relay contact terminal blocks.
ADDITIONAL FEATURES ACCESSORY FEATURES ON EXPANSION BOARD WIRING ACCESSORIES TO THE EXPANSION BOARD Refer to the chart below and the corresponding image for a description of the expansion board inputs. Open Input (& common) Open command - opens a closed gate. (3-Button Control Station, 4 terminals total) Soft close (maintained switch does not override external safeties and does not reset alarm condition) If maintained, pauses Timer-to-Close at OPEN limit.
100 to the secondary operator Bi-Part Delay Bi-Part Delay: ON (will open last Bi-Part Delay: OFF (will open Switch and close first) LiftMaster Internet Program to primary operator. first and close last) Gateway Tandem Mode: OFF Tandem Mode: OFF Garage Door Monitor Program to primary operator.
ADDITIONAL FEATURES GATE OPERATOR SETUP EXAMPLES GATE OPERATOR SETUP EXAMPLES The following are example setups for the gate operator. Your specific site requirements may be different. Always setup the operator system to the site requirements, including all necessary secondary entrapment protection systems. NOTE: We recommend that all accessories and board configurations are set on the primary operator. RESIDENTIAL SMALL One to four residential homes sharing a gated entrance/exit, allowing vehicle access trumps security concerns A residential community (more than four homes) having one or more gated entrances/exits, allowing vehicle access trumps security concerns...
ADDITIONAL FEATURES LIMIT SETUP WITH A REMOTE CONTROL LIMIT SETUP WITH A REMOTE CONTROL To set the limits using a remote control, first you will need a 3-button remote control that has been programmed for OPEN, CLOSE, and STOP. Refer to the Programming section.
The status as shown by the LiftMaster Internet Gateway app will be either “open” or “closed”. The gate operator can then be controlled through the LiftMaster Internet...
TROUBLESHOOTING CONTROL BOARD LEDS CONTROL BOARD LEDS The control board is equipped with many LEDs that have a variety of functions. The control board LEDs indicate the status of the operator, assist with programming, and diagnose potential problems with the operator. NOTE: When cycling or disconnecting power (ac/dc) to the control board, it is recommended that you unplug the J15 plug.
TROUBLESHOOTING CONTROL BOARD LEDS CONTROL BOARD LEDS CONTINUED... DIAGNOSTIC CODES LEDS YELLOW DIAGNOSTIC LED RED DIAGNOSTIC LED # BLINKS MEANING CORRECTION # BLINKS MEANING CORRECTION 2 BLINKS ID resistor failure Check ID resistor wiring, clear limit 2 BLINKS Current Sense Motor control circuit fault, replace settings and reset limits control board...
TROUBLESHOOTING TROUBLESHOOTING CHART TROUBLESHOOTING CHART FAULT POSSIBLE CAUSES CORRECTIONS Operator does a) No power to control board a) Check AC and battery power. not run and b) Open fuse b) Check fuses. diagnostic LED c) If on battery power only, low or dead batteries c) Charge batteries by AC or solar power or replace batteries.
Page 39
TROUBLESHOOTING TROUBLESHOOTING CHART FAULT POSSIBLE CAUSES CORRECTIONS Gate opens, but will a) Check DIAGNOSTIC LEDs a) Use Diagnostic code to identify issue. not close. b) Open control active b) Check all Open inputs for an active input. c) Close Entrapment Protection Device active c) Check all Entrapment Protection Device inputs for an active sensor.
Page 40
TROUBLESHOOTING TROUBLESHOOTING CHART FAULT POSSIBLE CAUSES CORRECTIONS Alarm sounds for 5 a) Double entrapment occurred a) Check for cause of entrapment (obstruction) detection and correct. Toggle the reset switch to shut off alarm and reset the operator. minutes or alarm sounds with a command.
WIRING DIAGRAM To protect against fire and electrocution: For continued protection against fire: • DISCONNECT power and battery BEFORE installing or servicing operator. • Replace ONLY with fuse of same type and rating. Field Wiring Field Wiring Edge Interrrupt Black White White Yellow...
REMOTE CONTROLS Chamberlain offers a variety of LiftMaster remote controls to satisfy your application needs. Single-button to 4-button, visor or key chain. The following remote controls are compatible with operators manufactured by Chamberlain after 1993. Contact your authorized LiftMaster dealer for additional details and options.
Page 45
Conveniently plugs into existing control board. Model LOOPDETLM LOOP DETECTOR Low power loop detectors mounted and wired separately inside control box. LiftMaster low power accessory. Model LD7LP VEHICLE SENSING PROBE The vehicle sensing probe is buried in the ground and can detect a car as it approaches and will then open the gate.
3 times with a command if the battery is low. Batteries do not perform well in extremely cold temperatures. For best performance, the batteries should be replaced every 3 years. Use only LiftMaster part 29-NP712 for replacement batteries. The operator comes with two 7AH batteries. Two 33AH (A12330SGLPK), with 33AH Battery Harness (K94-36596) may be used in place of the 7AH batteries.
The Chamberlain Group, Inc. (“Seller”) warrants to the first purchaser of this product, for the structure in which this product is originally installed, that it is free from defect in materials and/or workmanship for a period of 7 year residential/ 5 year commercial from the date of purchase [and that the CSL24V™ and CSL24VH™ are free from defect in materials and/or workmanship for a period of 7 year residential/ 5 year commercial from the date of purchase].