Removal Of The Control Tap (Manual Control Models); Removal Of The Pilot Assembly (Manual Control Models) - Flavel Windsor Installation, Maintenance & User Instructions

Flavel inset live fuel-effect gas fires
Table of Contents

Advertisement

4.3
Removing the Control Tap from the fire.
4.3.1
Remove the burner assembly as in section 4.1.
4.3.2
Pull the control knob off the control tap spindle.
4.3.3
Loosen and remove the two gas pipe retaining nuts from the control
tap and release the ends of the gas pipes from the control tap body.
Remove the push in thermocouple from the end of the control tap.
4.3.4
Unscrew the control tap locknut from the front of the control panel and
remove the control tap.
4.3.5
To refit a control tap, reassemble in reverse order noting that the control
tap locates with a flat in the control panel. Carry out a gas tightness
test after re-assembly.
4.4
Removing the Thermocouple
4.4.1
Remove the burner assembly as in section 4.1
4.4.2
Remove the push in thermocouple from the end of the control tap and
and remove the thermocouple retaining nut from the mounting bracket
on the burner assembly.
4.4.3
Re-assemble in reverse order and carry out a gas tightness test.