Remove the four mounting screws indicated in
photo A on the underside of the manifold panel.
Remove the burner valve control knobs by pulling
them straight forward off the valve shafts.
Next remove the ¼" hex head screws securing
each of the main top mounting clips. Remove the
1/4" hex head screw in the center of the manifold
panel and remove the panel from the range.
(Photo B)
With the manifold panel removed the surface
burner ignitor switches and harness are
accessible. The wire harness and switches are
replaced as a complete assembly.
To remove the switches and harness from the
burner valves loosen the wire twist ties that
secure the wire harness to the manifold pipe.
(Photo C)
Pull forward to unsnap the switch housing from
the valve. (Photo D).
When replacing the switches make sure that the
switches snap securely and lock to the valve
body. The slack in the wire harness should lay
under the manifold tube and secure with the wire
twist ties as shown in the photo.
Disconnect the compression nut that secures the
orifice holder assembly gas line to the valve.
Remove the valve mounting screw from the top
side of the manifold tube. The valve can now be
pulled out of the manifold tube from the bottom.
IMPORTANT NOTE:
burner valve always insure that the washer on
the burner screw and valve body is undamaged
and properly positioned

Removing Manifold Panel

Replacing ignitor switches and harness

Replacing Surface Burner Valves

When reinstalling the
Burner ignitor switches and
Valve
Mounting
screw
Page 33
Remove Three
Screws
twist ties
Harness
Compression
Nut
Washer
Burner Valve
Photo A
Photo B
Photo C
Photo D
& screw