Interface Selection; Db-25M Connector Pin Outs - SeaLevel ACB-MP+4.PCI User Manual

Table of Contents

Advertisement

Interface Selection

The ACB-MP+4.PCI supports a variety of electrical interfaces. Refer to the Control
and Status Register Definitions found in the Technical Description section of this
manual for this bit description. There is line termination on RXD, RXC, and TXC in
the following modes: RS-530, RS-530A, RS-485T, and V.35.
HEX
6,7,8,9

DB-25M Connector Pin Outs

RS-232 Signals
Base+5, M3-M0=2, 0010
Pin #
© Sealevel Systems, Inc.
M3
M2
0
0
0
1
0
0
2
0
0
3
0
0
4
0
1
5
0
1
0
1
A
1
0
B
1
0
C
1
1
D
1
1
E
1
1
F
1
1
Signal
2
TD
Transmit Data
3
RD
Receive Data
4
RTS
Request To Send
5
CTS
Clear To Send
6
DSR
Data Set Ready
7
GND
Ground
8
DCD
Data Carrier Detect
15
TXC
Transmit Clock
17
RXC
Receive Clock
18
LL
Local Loopback
20
DTR
Data Terminal Ready
21
RL
Remote Loopback
24
TSET
Transmit Signal Element Timing
M1
M0
0
0
All signals are high impedance
0
1
* not supported *
1
0
RS-232
1
1
* not supported *
0
0
RS-485T with 120Ω termination
0
1
RS-485 without termination
1
0
* not supported *
1
0
single ended loopback
1
1
differential loopback
0
0
* not supported *
0
1
RS-530
1
0
V.35
1
1
RS-530A
Name
Mode
Output
Input
Output
Input
Input
Input
Input
Input
Output
Output
Output
Output
- 7 -