USER MANUAL
Sealevel Systems, Inc
155 Technology Place
P.O. Box 830
Liberty, SC 29657 USA
ACB-MP. PCI
TM
Part # 5102
Phone:
(864) 843-4343
FAX:
(864) 843-3067
www.sealevel.com

Advertisement

Table of Contents
loading

Summary of Contents for SeaLevel ACB-MP.PCI

  • Page 1 ACB-MP. PCI USER MANUAL Part # 5102 Sealevel Systems, Inc Phone: (864) 843-4343 155 Technology Place FAX: (864) 843-3067 P.O. Box 830 www.sealevel.com Liberty, SC 29657 USA...
  • Page 2: Table Of Contents

    RS-530 / 530A..............................11 V.35..................................11 D - S ......................12 PPENDIX CREEN E - C ..................13 PPENDIX OMPLIANCE OTICES ..................13 EDERAL OMMUNICATIONS OMMISSION TATEMENT EMC D ..........................13 IRECTIVE TATEMENT ...........................14 ARRANTY © 2000i Sealevel Systems, Incorporated. All rights reserved.
  • Page 3: Introduction

    The ACB-MP.PCI also utilizes the Sipex-505 multi-protocol electrical interface chip that allows the ACB- MP.PCI to be compliant with EIA/TIA-530/530A, EIA/TIA-232E, EIA/TIA-485, and ITU V.35. What’s Included The ACB-MP.PCI is shipped with the following items. If any of these items are missing or damaged, contact the supplier. •...
  • Page 4: Installation

    Operation System Installation For Windows users that are using Sealevel’s SeaMAC software please note that there is a different install for this card than the normal SeaMAC software. When choosing to install the software from the CD scrool down to the SeaMAC drivers.
  • Page 5: Technical Description

    Technical Description Technical Description The ACB-MP.PCI utilizes the Zilog 85230 Enhanced Serial Communications Controller (ESCC). This chip features programmable baud rate, data format and interrupt control. Refer to the ESCC Users Manual for details on programming the 85230 ESCC chip.
  • Page 6: Interface Selection

    Technical Description Interface Selection The ACB-MP.PCI supports a variety of electrical interfaces. Refer to the Control and Status Register Definitions found in the Technical Description section of this manual for this bit description. There is line termination on RXD, RXC, and TXC in the following modes: RS-530, RS-530A, RS-485T, and V.35.
  • Page 7: V.35 Signals

    TSETB TSET+ Transmit Signal Element Timing Positive Output TSETA TSET- Transmit Signal Element Timing Negative Output DSRB DSR+ Data Set Ready Positive Input DSRA DSR- Data Set Ready Negative Input Local Loopback Output Remote Loopback Output Sealevel Systems ACB-MP.PCI Page 5...
  • Page 8: Rs-485 Or Rs-485T

    Receive Clock Negative Input TDB TX+ Transmit Positive Output TDA TX- Transmit Negative Output TSETB TSET+ Transmit Signal Element Timing Positive Output TSETA TSET- Transmit Signal Element Timing Negative Output Local Loop-back Output Remote Loop-back Output Sealevel Systems ACB-MP.PCI Page 6...
  • Page 9: Specifications

    350 mA Mean Time Between Failures (MTBF) Greater than 150,000 hours. (Calculated) Physical Dimensions Board length 4.75 inches (12.065 cm.) Board Height including Goldfingers 3.50 inches (8.890 cm.) Board Height excluding Goldfingers 3.175 inches (8.065 cm.) Sealevel Systems ACB-MP.PCI Page 7...
  • Page 10: Appendixa - Troubleshooting

    2. Make sure the Sealevel Systems adapter is securely installed in a PCI slot. 3. Use the supplied software and User Manual to verify that the Sealevel Systems adapter is configured correctly. The supplied software contains a diagnostic program “SSDMP” that will verify if the adapter is configured properly.
  • Page 11: Appendixb - How T O Get Assistance

    3. Sealevel Systems maintains a Home page on the Internet. Our home page address is www.sealevel.com. The latest software updates, and newest manuals are available via our FTP site that can be accessed from our home page.
  • Page 12: Appendixc - Electrical Interface

    +12 volts (usually +3 to +10 volts) represents a binary 0 (space) and -12 volts (-3 to -10 volts) denotes a binary 1 (mark). The RS-232 and the EIA/TIA-574 specification defines two type of interface circuits, Data Terminal Equipment (DTE) and Data Circuit-Terminating Equipment (DCE). The Sealevel Systems adapter is a DTE interface.
  • Page 13: Rs-530 / 530A

    RS-232. The physical connector is a 34-pin connector that supports 24 data, clock and control signals. The physical connector is defined in the ISO-2593 standard. ITU V.35 specification defines two types of interface circuits, Data Terminal Equipment (DTE) and Data Circuit-Terminating Equipment (DCE). The Sealevel Systems adapter is a DTE interface.
  • Page 14: Appendixd - Silk -Screen

    Appendix D - Silk-Screen Appendix D - Silk-Screen 3.5" 4.75" 3.175" Sealevel Systems ACB-MP.PCI Page 12...
  • Page 15: Appendixe - Compliance Notices

    Always use cabling provided with this product if possible. If no cable is provided or if an alternate cable is required, use high quality shielded cabling to maintain compliance with FCC/EMC directives. Sealevel Systems ACB-MP.PCI Page 13...
  • Page 16: Warranty

    Sealevel Systems, Inc. provides a lifetime warranty for this product. Should this product fail to be in good working order at any time during this period, Sealevel Systems will, at it's option, replace or repair it at no additional charge except as set forth in the following terms.