LOCATIONS 56- 83 ARE ONLY USED WHEN REPORTING EVENTS TO A PAGER OR USING A SLOW FORMAT
SUCH AS 4+2. WHEN USING CONTACT ID OR SIA, THERE IS NO NEED TO PROGRAM THESE LOCATIONS.
LOCATION 56
RESTORE
Location 56 contains the event code for a zone "Restore" for a 4+2 format. The digit programmed in this location will be
sent as the tens digit in place of the alarm event code. The zone ID will always be reported as the ones digit of the
zone number (i.e. 9 for zone 9). Any segment left as "0" will follow the Segment 1 selection.
Segment 1 = Partition #1 Restore Code
LOCATION 57
BYPASS
Location 57 contains the event code for a zone "Bypass" for a 4+2 format. The digit programmed in this location will be
sent as the tens digit. The zone ID will always be reported as the ones digit of the zone number (i.e. 9 for
zone 9). Any segment left as "0" will follow the Segment 1 selection.
Segment 1 = Partition #1 Bypass Code
LOCATION 58
TAMPER
Location 58 contains the event code for a zone "Tamper" for a 4+2 format. The digit programmed in this location will be
sent as the tens digit. The zone ID will always be reported as the ones digit of the zone number (i.e. 9 for
zone 9). Any segment left as "0" will follow the Segment 1 selection.
Segment 1 = Partition #1 Tamper Code
LOCATION 59
TROUBLE
Location 59 contains the event code for a zone "Trouble" for a 4+2 format. The digit programmed in this location will be
sent as the tens digit. The zone ID will always be reported as the ones digit of the zone number (i.e. 9 for
zone 9). Any segment left as "0" will follow the Segment 1 selection.
Segment 1 = Partition #1 Trouble Code
LOCATION 60
SENSOR LOW BATTERY
Location 60 contains the event code for a zone "Sensor Low Battery" for a 4+2 format. The digit programmed in this
location will be sent as the tens digit. The zone ID will always be reported as the ones digit of the zone number
(i.e. 9 for zone 9). Any segment left as "0" will follow the Segment 1 selection.
Segment 1 = Partition #1 Sensor Low Battery Code
LOCATION 61
SENSOR MISSING
Location 61 contains the event code for a zone "Sensor Missing" for a 4+2 format. The digit programmed in this location
will be sent as the tens digit. The zone ID will always be reported as the ones digit of the zone number (i.e. 9
for zone 9). Any segment left as "0" will follow the Segment 1 selection.
Segment 1 = Partition #1 Sensor Missing Code
LOCATION 62
DURESS
Location 62 contains the tens and ones digits that will be sent for a 4+2 format if the Duress code is enabled in location
44. Segment 1 contains the tens digit, segment 2 contains the ones digit.
LOCATION 63
KEYPAD AUXILIARY 1
Location 63 contains the tens and ones digits that will be sent for a 4+2 format if the keypad "Auxiliary 1" (FIRE) is
enabled in the partition feature selection. Segment 1 contains the tens digit, segment 2 contains the ones digit.
LOCATION 64
KEYPAD AUXILIARY 2
Location 64 contains the tens and ones digits that will be sent for a 4+2 format if the keypad "Auxiliary 2" (MEDICAL) is
enabled in the partition feature selection. Segment 1 contains the tens digit, segment 2 contains the ones digit.
Page 24
SLOW FORMAT COMMUNICATOR CODES
2 segments, numerical data
Segment 2 = Partition #2 Restore Code
2 segments, numerical data
Segment 2 = Partition #2 Bypass Code
2 segments, numerical data
Segment 2 = Partition #2 Tamper Code
2 segments, numerical data
Segment 2 = Partition #2 Trouble Code
2 segments, numerical data
Segment 2 = Partition #2 Sensor Low Battery Code
2 segments, numerical data
Segment 2 = Partition #2 Sensor Missing Code
2 segments, numerical data
2 segments, numerical data
2 segments, numerical data