LOCATION 41
SPECIAL FEATURES
LOCATION 42
GO TO PROGRAM CODE
Location 42 contains the "Go To Program Code". This location contains either a 4 or 6-digit code. If the 6-digit code
option is enabled in Location 41, this code must contain six (6) digits. If this option is not enabled in location 41, the last
2 segments (digits) will be ignored. With the NX-6 disarmed, the "Go To Program Code" can be used to enter the
Program Mode.
GO TO PROGRAM CODE PARTITION AND
LOCATION 43
AUTHORIZATION
The "Go To Program Code" can be used as a standard arm/disarm code. When using the code to arm or disarm, the user
ID is 255. (This code may not be changed in the Run Mode.)
Segment 1
Segment 2
LOCATION 44
DURESS CODE
Location 44 contains the "Duress" code. This Location contains either 4 or 6 digits. If the 6-digit code option is enabled
in Location 41, this code must contain six (6) digits. If the 6-digit option is not enabled in location 41, the last 2 digits
will be ignored. If the duress code is programmed, it will work for all partitions.
LOCATION 45
AUXILIARY OUTPUT, PARTITION SELECTION
Location 45 is used to select which partition(s) the events must occur in before the output will activate. Location 45 has
4 segments. Segment 1 corresponds to Output 1, and Segment 4 corresponds to Output 4.
Segments
1 - 4
LOCATION 46
AUXILIARY OUTPUT, SPECIAL TIMING
Location 46 contains special timing feature activation for the four auxiliary outputs. Segment 1 corresponds to Auxiliary
Output 1, Segment 4 corresponds to Auxiliary Output 4.
Segments
1 - 4
â On enables the 6-digit code option. If 6-digit option is enabled, all arm/disarm codes and
the "Go To Program Code" are 6 digits. If this option is enabled, the default user #1 code
is [1]-[2]-[3]-[4]-[5]-[6]. NOTE: IF YOU ENABLE THIS OPTION, VERIFY THAT THE
"GO TO PROGRAM CODE" IS A 6-DIGIT CODE BEFORE EXITING PROGRAMMING.
ã On requires code entry for [r]-[9]-[8] ACall back for download@ and [r]-[9]-[9] AAnswer
incoming call for download@ functions.
ä On enables AAuto Cancel/Abort@. Refer to feature definitions beginning on page 3.
å On enables AWalk-Test Mode@. Refer to feature definitions beginning on page 3.
Ò - é Reserved.
â Reserved.
ã On enables "Go To Program Code" as an arm only code.
ä On enables "Go To Program Code" as an arm only after closing.
å On enables "Go To Program Code" as a master arm/disarm code (can change user codes)
æ On enables "Go To Program Code" as an arm/disarm code.
ç On enables "Go To Program Code" to bypass zones.
è On enables "Go To Program Code" opening and closing reports.
é Reserved.
â On enables the "Go To Program Code" for Partition #1.
ã On enables the "Go To Program Code" for Partition #2.
â Partition #1
ã Partition #2
â On if output should be timed in minutes; Off if timed in seconds.
ã On if output should latch; Off if output should be timed.
ä On if output should stop timing upon code entry; Off if the output should continue to time
upon code entry.
å On if output should only activate between the closing and opening time in loc. 52 and 53.
æ On if output should only activate between the opening and closing time in loc. 52 and 53.
ç On if output should be inverted (0 volts going to 12 volts when activated).
è Reserved.
é Reserved.
1 segment, feature selection
6 segments, numerical data
2 segments, feature selection
6 segments, numerical data
4 segments, feature selection
4 segments, feature selection
Page 21