Communicator Format Selections - GE NetworX NX-6 Installation And Startup

Networx series
Hide thumbs Also See for NetworX NX-6:
Table of Contents

Advertisement

LOCATION 3
DIAL ATTEMPTS/BACKUP CONTROL PHONE # 1
Segment 1
Dial attempts: Location 3, Segment 1 is used to enter the number of dial attempts (1 to 15 Attempts)
the communicator will make to Phone #1 before ending the notification process.
communicator will make eight (8) attempts to the first number.
Segment 2
Phone #1 Backup Control: Programming a "0" in Segment 2 of this location will cause the NX-6 to
make the designated number of attempts to Phone #1 and #2 before setting the "Fail To Communicate" condition and
stop reporting. Programming a "1" in this segment will cause the NX-6 to stop trying to communicate after the
designated number of attempts have been made to Phone #1. If a "2" is programmed in this segment, it will cause the
NX-6 to make the dial attempts in increments of two. The first two attempts will be made to Phone #1, the next two
attempts to Phone #2, then repeating until the total number of attempts designated in Segment 1 is completed.
DATA
FORMAT
0
Local
1
Universal 4+2
2
3+1 fast (or 4+1)
3
Reserved
4
Pager
5
3/1 or 4/1 slow
6
3/1 or 4/1 slow
7
3/1 or 4/1 fast
8
3/1 or 4/1 fast
9
3/1 or 4/1 fast with
parity
10
3/1 or 4/1 fast with
parity
11
4+2 express
12
4+2 fast
13
Ademco Contact ID
14
SIA
15
Custom format
LOCATION 4
EVENTS REPORTED TO PHONE # 1
Phone #1 has two programming locations that are used to select which events are reported to this phone number.
Location 4 is used to select which events are reported to Phone #1.
reported to Phone #1. If dual or split reporting is not desired, location 4 should be used to select all events to Phone
#1 and location 5 should be left at the factory default of "0". If dual or split reporting is desired, and the split is based on
the event type (such as alarm, open/close, etc.), location 4 should be used to select only those events that should be
reported to Phone #1 and location 5 should be left at the factory default of "0". If dual or split reporting is desired, and
the split is based on partition, location 4 should be programmed as a "0" and location 5 should be used to select those
partitions that should be reported to Phone #1. If no events should be reported to Phone #1, both locations should be
programmed as "0" (disabling all options). Use Table 1.1 on page 14 to identify the events to be reported for
Phone #1.

COMMUNICATOR FORMAT SELECTIONS

Communicator is disabled
Two digit event code 1800hz transmit 2300hz handshake double round parity 40pps
One digit event code 1900Hz transmit 1400Hz handshake double round parity 20pps
Reserved
3 digit event code DTMF transmission
1800hz transmit 2300hz handshake double round parity 20 p.p.s. hex capability
1800hz transmit 1400hz handshake double round parity 20 p.p.s. hex capability
1800hz transmit 2300hz handshake double round parity 40 p.p.s. hex capability
1800hz transmit 1400hz handshake double round parity 40 p.p.s. hex capability
1800hz transmit 2300hz handshake single round w/parity 40 p.p.s. hex capability
1800hz transmit 1400hz handshake single round w/parity 40 p.p.s. hex capability
Two-digit event code DTMF transmission
Two-digit event code 1900hz transmit 1400hz handshake double round parity 20
p.p.s.
DTMF (see pages 37-38)
FSK (see pages 37-38)
(See location 18, page 16)
2 segments, numerical data
Factory default is "8" and the
DESCRIPTION
2 segments, feature selection
Location 5 is used to select which partitions are
Page 13