GE NetworX NX-6 Installation And Startup page 19

Networx series
Hide thumbs Also See for NetworX NX-6:
Table of Contents

Advertisement

LOCATION 23
PARTITION 1
FEATURE AND REPORT SELECTIONS
Location 23 is used to enable certain features that can be accessed or are visible to the user from the keypad of the
system. In addition, certain communicator reports are enabled in location 23. Each of these features can be enabled by
partition. For additional partition information see locations 88-91 on page 27.
any partition is left blank, that partition will use this location for the feature selection. This location contains 3
segments of 8 features each. (See the definitions beginning on page 3.)
â On enables the Quick Arm feature.
ã On enables the Re-exit feature.
Segment 1
ä On enables the Automatic Bypass feature.
å On enables the Silent Keypad Panic feature (overrides the audible panic selection).
æ On enables the Audible Keypad Panic feature.
ç On enables the Keypad Aux 1 feature (FIRE).
è On enables the Keypad Aux 2 feature (MEDICAL).
é On enables the Keypad Multiple Code Attempt Tamper feature.
â On enables the LED Extinguish feature.
ã On enables the Require Code for Bypassing feature.
Segment 2
ä On enables the Zone Bypassed Sounder Alert feature.
å On enables the AC Power/Low Battery Sounder Alert feature.
æ On enables Bypass toggle.
ç On enables Silent Auto Arm.
è On enables the Automatic Instant feature.
é Reserved.
â On enables Opening and Closing reports.
ã On enables Zone Bypass reporting.
Segment 3
ä On enables Zone Restore reporting.
å On enables Zone Trouble reporting.
æ On enables Zone Tamper reporting.
ç On enables the Cancel reporting.
è On enables the Recent Closing report.
é On enables the Exit Error report.
LOCATION 24
ENTRY / EXIT TIMERS
Location 24 is used to program the Entry/Exit times. There are 2 separate Entry/Exit times.
Entry time 1
Segment 1
Segment 2
Entry time 2 This is the entry time that will be used when a delay 2 zone type initiates an
Segment 3
Segment 4
NOTE: The combined Entry Delay (loc 24) and Dial Delay (loc 40) must not exceed 1 minute for SIA CP-01
requirements.
This is the entry time that will be used when a delay 1 zone type initiates an
entry delay. Valid entries are 30-255 seconds.
Exit time 1
This is the exit time that will be used for all zones designated as delay 1. Valid
entries are 45-255 seconds.
entry delay. Valid entries are 30-255 seconds.
Exit time 2
This is the exit time that will be used for all zones designated as delay 2. Valid
entries are 45-255 seconds.
3 segments, feature selection
If the feature selection location for
4 segments, numerical data
Page 17