Segment 4
Segment 5
LOCATION 38
SWINGER SHUTDOWN COUNT
Location 38 contains the number of trips on a zone before that zone is bypassed automatically. Refer to the feature
definitions beginning on page 3. Factory default is 1.
LOCATION 39
KEYPAD SOUNDER CONTROL
LOCATION 40
SYSTEM TIMERS
Location 40 contains the duration of various system timing functions. Example: If you desire the duration of the
Dynamic Battery Test to be 30 minutes, you should program [3]-[0]-[r] in segment 1 of this location. The [3]-[0] is the
number of minutes, and the [r] stores the data and moves to the next segment of this location.
SEGMENT
DESCRIPTION
1
Dynamic Battery Test
duration
2
AC Fail report delay
3
Power Up delay
4
Siren time
5
Telephone Line Cut delay
6
Cross Zone time
7
Chime time in 50 mS
(1/20th second) increments
8
Dial delay
9
Fire Alarm Verification time
10
Listen-In time
Page 20
â On if Fail To Communicate report enabled.
ã On if Log Full report enabled.
ä On if Autotest report enabled.
å On if Start/End programming report enabled.
æ On if End Download report enabled.
ç On if Sensor Low Battery report enabled.
è On if Sensor Missing report enabled.
é Reserved.
â On enable Lost Clock service light.
ã On enables Zone Doubling for zones 7 -12 (requires NX-200 Zone Doubling Kit).
ä On disables on-board zones.
å On will allow two trips on same cross-zone to activate an alarm.
æ On will not allow zones that are force armed to report bypass.
ç Reserved
è Use internal crystal for clock.
é Disable Temporal Siren on Fire. (Note: Must not be disabled for UL listed systems.)
Refer to the feature definitions beginning on page 3.
â On if keypad sounds for ATelephone Line Cut@ when the system is armed.
ã On if keypad sounds for ATelephone Line Cut@ when disarmed.
ä On if keypad sounds upon AC Power Failure.
å On if keypad sounds when a Low Battery is detected.
æ On if keypad sounds during Cross Zone trip time.
ç On if keypad sounds for zone and box tampers.
è Reserved.
é On if keypad sounds for expander trouble (required for UL installations).
SELECTIONS
0 - 255 minutes
0 - 255 minutes
0 - 60 seconds
1 - 254 minutes
0 - 255 seconds
0 - 255 minutes
0 - 255 mS
15 - 255 seconds
120 - 255
seconds
0 - 255 seconds
1 segment, feature selection
10 segments, numerical data
DEFAULT
0
"0" = no test
The "Dynamic Battery Test" feature cannot
exceed 4 hours for UL residential fire
installations.
5
0 = no delay
60
0 = no delay
8
0
0 = no TLM
5
0 = no Cross Zoning
3
255 mS = 12 seconds
0 follows zone, 255 is latched
30
The "Dial Delay" feature shall be set to –0- for
UL Listed systems. Must be disabled by zone
type in Loc 110-169.
The combined Dial Delay and Entry Delay (loc
24) must not exceed 1 minute fro SIA CP-01
requirements.
0
0= no Fire Alarm Verification
This feature is not approved for residential
use in California.
0
0 = no Listen-In time
The "Listen-In" feature cannot be enabled for
UL Listed systems.
NOTES