H3C VG 21-08 Voice Gateway
voltage introduced from the exterior network is also channeled to the
ground through the grounding cable.
The grounding screw of PGND is located on the rear panel.
Connect this screw to earth ground using a grounding cable. The
grounding resistance should not be greater than 5 ohm.

3.4 Connecting to the Console Terminal

I. Console port
The VG 21-08 provides a consol port, through which you can
configure the device.
II. Console cable
The console cable is an 8-core shielded cable. At one end of the
cable is an RJ-45 connector that can be plugged to the console port of
the VG 21-08; at the other end is a DB9 (female) connector, which can
be plugged to the serial port of the console terminal.
The following figure illustrates a console cable:

Figure 3-2 Console cable assembly

III. Connecting the Console cable
When configuring the VG 21-08 through a console terminal,
follow these steps to connect the console cable:
Chapter 3 Installing the VG 21-08