Safety Precautions; General Description; Table 1. Specifications - Cornelius Remcor TJ45-D Operator's Manual

Dual ice dispenser
Table of Contents

Advertisement

Always disconnect power to the dispenser before servicing or cleaning.
Never place hands inside of hopper or gate area without disconnecting power to the dispenser. Agitator rotation
occurs automatically when the dispenser is energized!
This ice dispenser has been specifically designed to provide protection against personal injury and eliminates
contamination of ice. To insure continued protection and sanitation, observe the following
ALWAYS be sure the removable lid is properly installed to prevent
unauthorized access to the hopper interior and possible contamination of ice.
ALWAYS be sure the upper and lower front panels are securely fastened.
ALWAYS keep area around the dispenser clean of ice cubes.
CAUTION: Dispenser cannot be used with crushed or flaked ice.
Use of bagged ice which has frozen into large chunks can void warranty. The dispenser
agitator is not designed to be an ice crusher. Use of large chunks of ice which "jam up"
inside the hopper will cause failure of the agitator motor and damage to the hopper. If bagged ice
is used, it must be carefully and completely broken into small, cube-sized pieces before filing into
the dispenser hopper.
The Remcor " TJ"series of ice dispensers will solve ice service needs in the sanitary, space saving, economical
way. Designed to be manually filled with ice from any remote ice making source, these dispensers will dispense
cubes (up 1"in size), cubelets, hard-chipped or cracked ice.
CAUTION: Dispenser cannot be used with crushed or flaked ice. Use of bagged ice, which
has frozen into large chunks can void warranty. The dispenser agitator is not designed to
be an ice crusher -- use of large chunks of ice which "jam--up" inside the hopper will cause
failure of the agitator motor and damage to the hopper. If bagged ice is used it must be carefully
and completely broken into small, cube-size pieces before filling into the dispenser hopper.

SAFETY PRECAUTIONS

GENERAL DESCRIPTION

Table 1. Specifications

Model:
Ice Storage Capacity:
Electrical:
Drain Connection:
Electrical Connection:
Dimensions:
Model:
Ice Storage Capacity:
Electrical:
Drain Connection:
Electrical Connection:
Dimensions:
1
TJ45-D
45 lbs.
120/1/60 3AMP
3/4" F.P.T.
6' , 3-wire cord with 3-prong ground-type plug
26½ "H x 16"W x 22"D
TJ90-D
90 lbs.
120/1/60 3AMP
3/4" F.P.T.
6' , 3-wire cord with 3-prong ground-type plug
30"H x 22" W x 28"D
90665