Download Print this page

Technical Data - Gardena accuCut Operating Instructions Manual

Turbotrimmer

Advertisement

Fault
The Trimmer is not cutting
cleanly or not cutting at all
Charging indicator lamp does
not light up
Charging indicator lamp
flashes for more than
1 hour
The battery can no longer
be charged
In the event of other faults please contact GARDENA Service.
A
Repairs should only be carried out by GARDENA service centres or dealers
authorised by GARDENA.

9. Technical Data

Battery
Battery capacity
Battery charging time
Idling time
Battery charger
Mains voltage
Rated output current
Max. output voltage
Cutting width
Weight
Rpm of blade carrier
Working area related emission
characteristic value L
Noise level L
2)
WA
Hand / arm vibration a
Measuring method according to 1) EN 786 2) directive 2000 /14 / EC
10. Accessories
GARDENA Spare Blade for
Turbotrimmer accuCut
Spare Batteries
Possible cause
Blade worn or too short.
Blade broken off.
Battery is flat.
Battery charger or charging cable v Plug in battery charger and
not plugged in properly.
A fault has occurred.
If this does not eliminate the fault, please contact
GARDENA Service.
Battery is defective.
Turbotrimmer accuCut (Art. 2417)
lithium ion (18 V)
1.6 Ah
approx. 10 hrs
approx. 40 mins (with full battery)
230 V / 50 Hz
200 mA
22 V (DC)
230 mm
1.9 kg
9,000 rpm
72 dB (A)
pA 1)
measured 83 dB (A) / guaranteed 84 dB (A)
1)
< 2,5 m / s
2
vhw
20 pcs.
For Turbotrimmer accuCut Art. 2417
Remedy
v Replace blade.
v Replace blade.
v Charge battery.
charging cable properly.
v Unplug and reinsert
charging cable. The fault
will be reset.
v To replace battery please
contact GARDENA Service.
Art. 5368
Available via
GARDENA Service
17

Advertisement

loading

This manual is also suitable for:

Accucut 2417