Vdsl-Ethernet-Related Commands; Figure 23-8 Vdsl Monitor; Figure 23-9 Ethernet Status Counters; Table 23-6 Ethernet Status Counters - ZyXEL Communications VES-1000 Series User Manual

Vdsl-ethernet switch
Hide thumbs Also See for VES-1000 Series:
Table of Contents

Advertisement

ves100> vdsl mon vdsl01 on
ves100> vdsl01:VDSL:US 16.67Mbps SNR 36.43dB RSERR 0 DS 16.67Mbps SNR 42.71dB RS
ERR 0
vdsl01:VDSL:US 16.67Mbps SNR 36.34dB RSERR 0 DS 16.67Mbps SNR 42.54dB RSERR 0
vdsl01:VDSL:US 16.67Mbps SNR 36.40dB RSERR 0 DS 16.67Mbps SNR 42.60dB RSERR 0
vdsl01:VDSL:US 16.67Mbps SNR 36.54dB RSERR 0 DS 16.67Mbps SNR 42.57dB RSERR 0
vdsl01:VDSL:US 16.67Mbps SNR 36.36dB RSERR 0 DS 16.67Mbps SNR 42.68dB RSERR 0
vdsl01:VDSL:US 16.67Mbps SNR 36.46dB RSERR 0 DS 16.67Mbps SNR 42.62dB RSERR 0
Refer to Table 23-5 for more information on these fields.
23.3

VDSL-Ethernet-related Commands

Please refer to the sections about 10/100M auto-sensing Ethernet, Ethernet port trunking and Ethernet port setup
for more information on Ethernet.
23.3.1
View Ethernet Status Counters
vdsl enet status chan-id
This command displays the current Ethernet counters of the VES and VDSL modem.
ves100> vdsl enet st vdsl01
VDSL Channel vdsl01:
LT Ethernet Counters:
ALGM_ERR = 0
LATE_COL = 0
FTL_ERR = 0
BCF = 0
RXBCNT = 0
NT PHY: LSI 80225
NT Ethernet speed: 100M Full Duplex
NT Ethernet Counters:
ALGM_ERR = 0
LATE_COL = 0
FTL_ERR = 0
BCF = 67493
RXBCNT = 75138
ves100>
The following table explains these parameters.
COUNTER
ALGM_ERR
This is the number of frames received with alignment errors (odd number of nibbles).
SINGLE_COL
A count of successfully transmitted frames for which transmission is inhibited by exactly one
collision.
MUL_COL
A count of successfully transmitted frames for which transmission was inhibited by more than
one collision.
VDSL-Related Commands

Figure 23-8 VDSL Monitor

SINGLE_COL = 0
EXC_COL = 0
FCS_ERR = 0
RXPAUS = 0
TX_DEF = 0
SINGLE_COL = 0
EXC_COL = 0
FCS_ERR = 0
RXPAUS = 0
TX_DEF = 0

Figure 23-9 Ethernet Status Counters

Table 23-6 Ethernet Status Counters

VES-1000 Series Ethernet Switch
MUL_COL = 0
MACRX_ERR = 0
CS_ERR = 0
OTO = 13641294
ORO = 0
TXPAUS = 0
TXBCNT = 75120
MUL_COL = 0
MACRX_ERR = 1
CS_ERR = 0
OTO = 0
ORO = 13642095
TXPAUS = 0
TXBCNT = 0
MEANING
23-9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ves-1008aVes-1012

Table of Contents