5-3-10. Convergence Adjustment of 14-Inch
Model
• Preparation
Refer to "3. SET-UP Adjustment (3-7-3. 14-Inch Model
Convergence Adjustment)" (Page 3-10).
• Convergence adjustment
Adjust V STATIC BOTTOM data and V STATIC TOP data
so that a vertical mis-convergence is minimized at the top
and bottom areas of the screen.
Note: V STATIC BOTTOM data and V STATIC TOP data
adjustment menu is under E BOARD menu of
MAINTENANCE menu. (See Fig. 1-22)
• 4:3 UNDER SCAN mode convergence adjustment
Refer to "3. SET-UP Adjustment (3-7-3. 14-Inch Model
Convergence Adjustment)" (Page 3-10).
• 16:9 NORMAL SCAN mode convergence adjustment
Refer to "3. SET-UP Adjustment (3-7-3. 14-Inch Model
Convergence Adjustment)" (Page 3-10).
• 16:9 UNDER SCAN mode convergence adjustment
Refer to "3. SET-UP Adjustment (3-7-3. 14-Inch Model
Convergence Adjustment)" (Page 3-10).
5-13