5-1-3. Adjustments 3
Perform the following adjustments using the RGB input sig-
nals. Set as follows at the INPUT CONFIGURATION menu
of the SETUP menu.
FORMAT ............. COMPONENT RGB
SLOT NO ............. 6
SYNC MODE ...... INT
1. RGB Signal SETUP Adjustment
Note: The following adjustment menus are under the BK
BOARD menu of the MAINTENANCE menu.
R SETUP
G SETUP
B SETUP
1. Input 100 IRE RGB signal.
2. Connect the oscilloscope to TP104.
3. Adjust the R SETUP data so that the black level and
setup signal level become equal.
4. Connect the oscilloscope to TP304.
5. Adjust the G SETUP data so that the black signal level
and setup signal level become equal.
6. Connect the oscilloscope to TP504.
7. Adjust the B SETUP data so that the black signal level
and setup signal level become equal.
5-8
Fig. 5-16
Level difference: 0 ±2 mV
Equalize