Sony TRINITRON BVM-14G1A Operation And Maintenance Manual page 25

Color video monitor
Hide thumbs Also See for TRINITRON BVM-14G1A:
Table of Contents

Advertisement

Setting Lists in the COLOR TEMP ADJ Menu
This section explains the setting lists displayed in the
menu.
How to read the setting lists
• For purposes of explanation, each setting list is
preceded by a menu number. These numbers are not
displayed on the screen.
For more information about the menu number, see "About
menu numbers" on page 19.
• The arrow mark (÷) refers you to another setting list
that appears after you make the setting, or to an
operation that is carried out as a result of the setting.
When there is no arrow mark, the menu does not have
any sub-list.
[B] COLOR TEMP ADJ menu (STD/COL1/
COL2)
Select the adjustment method.
MANUAL: Set with the MANUAL knob. ÷[B1]
PROBE: Set using a probe. ÷[B2]
COPY: Copy data from elsewhere. ÷[B3]
TRIM: Perform fine adjustments after setting the
color temperature. ÷[B4]
[B1] MANUAL menu (STD/COL1/COL2)
Adjust the gain and bias manually.
ADJUST: Adjust the gain and bias. To shift between
gain adjustment and bias adjustment, press UP/
DOWN buttons. Use appropriate knobs in each
adjustment as described below. After the
adjustment, press the ENTER button to confirm the
adjusted values.
RED: CONTRAST knob (Adjust the R gain or
bias with the CONTRAST knob.)
GREEN: BRIGHT knob (Adjust the G gain or
bias with the BRIGHT knob.)
BLUE: CHROMA knob (Adjust the B gain or bias
with the CHROMA knob.)
LUMINANCE: PHASE knob (Adjust luminance
with the PHASE knob.)
To reset RED/GREEN/BLUE to the value
before adjustment
When you are adjusting the gain or bias using the
MANUAL adjustment knobs, you can reset the
setting to the one before adjustment by pressing the
corresponding MANUAL button.
To reset all of settings at the same time, press the
PHASE button.
Note
You cannot reset the setting after you press the
ENTER button.
ORIGINAL VALUE: Set the initial value.
STD: Use common data (factory setting: D93).
COL1: Use common data (factory setting: D65).
COL2: Use common data (factory setting: D93).
SIGNAL: Select the white signal to be used for
adjustment.
INT: Use an internal signal. Simultaneously with
the adjustment of the gain and bias, the 100
IRE and 20 IRE signals are automatically
switched.
EXT: Use an external input signal. When adjusting
the gain and bias, input the proper signal.
To access the MANUAL menu directly
When the [F2] button is assigned as the short-cut
key to the MANUAL menu, you can directly
access the MANUAL menu that corresponds to the
color temperature setting set to the image on the
screen.
For details of how to assign the short-cut key, see
"Setting the Power-Up Conditions (SET UP 4) -
SYSTEM CONFIGURATION Menu" on page 39.
[B2] PROBE menu(STD/COL1/COL2)
Select the probe for color temperature adjustment.
SONY
BKM-14L...: Use the BKM-14L.
÷[B21]
GRASEBY
SLS 9400...: Use the SLS 9400.
÷[B213]
MINOLTA CA-100...: Use the CA-100. ÷[B213]
PHILIPS
PM 5639...: Use the PM 5639.
÷[B213]
THOMA
TF6...: Use the TF6. ÷[B213]
• If you cannot execute an ADJUST or ANALYZE
menu operation when using the Sony BKM-14L
probe, try again after disconnecting and reconnecting
the probe.
• When using the Thoma TF6 probe, set the TF6
PRINT menu to off.
2 9
Adjusting the Color Temperature — COLOR TEMP ADJ Menu
[B13] COPY SOURCE menu (STD/COL1/COL2)
Select the adjustment method and the source to be
copied from.
OTHER VALUE: Copy data from one of STD, COL
1 or COL 2. ÷[B31]
OTHER MONITOR: Copy data from another
monitor. ÷[B32]
MEMORY CARD: Copy data from a memory card.
÷[B33]
[B4] TRIM menu (STD/COL1/COL2)
Trim the original setting by selecting ADJUST.
ADJUST: Adjust the gain and bias. To shift between
gain adjustment and bias adjustment, press UP/
DOWN buttons. Use appropriate knobs in each
adjustment as described below. After the
adjustment, press the ENTER button to confirm the
adjusted values.
RED: CONTRAST knob (Adjust the R gain or
bias with the CONTRAST knob.)
GREEN: BRIGHT knob (Adjust the G gain or
bias with the BRIGHT knob.)
BLUE: CHROMA knob (Adjust the B gain or bias
with the CHROMA knob.)
LUMINANCE: PHASE knob (Adjust luminance
with the PHASE knob.)
To reset RED/GREEN/BLUE to the value
before adjustment
When you are adjusting the gain or bias using the
MANUAL adjustment knobs, you can reset the
setting to the one before adjustment by pressing the
corresponding MANUAL button.
To reset all of settings at the same time, press the
PHASE button.
TRIM: Select whether to add the fine adjustment to
the original setting (gain and bias set in MANUAL
menu [B1]).
APPLY: Adds the fine adjustment to the original
setting.
When APPLY is selected, "XX/TRIM"
(XX: the selected color temperature among
STD, COL 1 or COL 2) appears on the left
top on the COLOR TEMP ADJ menu.
NOT APPLY: Reset the setting to the original
setting (gain and bias set in MANUAL menu
[B1]).
3 0
SIGNAL: Select the white signal to be used for
adjustment.
INT: Use an internal signal. Simultaneously with
the adjustment of the gain and bias, the 100
IRE and 20 IRE signals are automatically
switched.
EXT: Use an external input signal. When adjusting
the gain and bias, input the proper signal.
Note
Even if NOT APPLY of the TRIM item is selected,
pressing the ENTER button to confirm the adjusted
values results in that APPLY will be selected.
[B21] PROBE menu (STD/COL1/COL2)
Select the BKM-14L operation.
ADJUST: Perform automatic color temperature
adjustment. ÷[B211]
ANALYZE: Display readout values on the screen.
÷[B212]
[B31] OTHER VALUE menu (STD/COL1/
COL2)
Select STD, COL1,or COL2. ÷ Copy is carried out.
STD: Copy common data (factory setting: D93).
COL1: Copy common data (factory setting: D65).
COL2: Copy common data (factory setting: D93).
D65: Copy the color temperature of D65.
D93: Copy the color temperature of D93.
[B32] OTHER MONITOR menu (STD/COL1/
COL2)
Specify the address number of the monitor.
MONITOR ADDRESS: Input the address number of
the monitor from which the data will be copied.
÷[B321]
[B33] MEMORY CARD menu
Select the file name. ÷[B331]
FILE NAME: Select the file name.