Table 29: Sensor/user report codes
Arm or disarm from
Panel or remote handheld touchpad
Key fob
Panel auxiliary panic
Panel tamper
Panel police panic
Panel fire panic
Dealer access code
Installer access code
Master code
Access codes 1 to 8
Duress code

Two-way voice operation

For the central station operator to initiate an audio session:
1. After the panel has completed reporting the alarm, pick up the CS phone and
press the * button to start the audio session.
2. Press 1 or 0 to speak, 2 for VOX operation, and 3 or 6 to listen.
3. Press 99 to terminate the session.
Note:
Panel voice announcements are silenced during AVM sessions. If the operator
does not terminate the session correctly, panel announcements may not occur for up
to 90 seconds after the operator hangs up.
Table 30: Audio verification set
Phone button
0 or 1
2
3 or 6
7
88
99
48
Reports as user
0
1 to 40 (sensor number)
41
42
43
44
44
45
46
47 to 54
55
Function
Speak
VOX operation
Listen
Extend session for 90 more seconds
Terminates session with call back (the panel answers on
the first ring if called within 5 minutes)
Terminates session with no call back
Simon XT Installation Manual