GE Simon XT Installation Manual page 49

Hide thumbs Also See for Simon XT:
Table of Contents

Advertisement

Table 27: Sensor tripping instructions
Sensor
Door/window
Freeze
Water
Carbon monoxide alarm
Glassbreak
Motion sensor
Rate-of-rise heat detector
Shock
Smoke
Personal help button
Key fob
Simon XT talking touch screen
Simon XT talking touchpad
Remote handheld touchpad
Sensor test failure
If sirens do not beep when a sensor is tripped, use an RF Sniffer (60-401) test tool to
verify that the sensor is transmitting. Constant beeps from the RF Sniffer indicate a
faulty sensor. Replace the sensor.
If possible, locate sensors within 100 ft. (30 m) of the panel. While a sensor may have
a range of 500 ft. (152 m) or more out in the open, the environment at the installation
site can have a significant effect on transmitter range. A change in sensor location
may help overcome adverse wireless conditions.
Simon XT Installation Manual
Do this
Open the secured door or window.
Remove the sensor cover. Apply ice in a plastic bag to the sensor
(for 10 to 15 minutes). Do not allow the sensor to get wet.
Press a wet rag or wet finger over both of the round, gold-plated
terminals on the underside of the sensor.
Press and hold the Test/Hush button (approximately 5 seconds)
until the unit beeps two times and then release the button.
Trip the glassbreak sensor with an appropriate glassbreak test
tool.
Avoid the motion sensor field of view for 5 minutes, and then
enter its view.
Rub your hand together until warm, and then place one hand on
the detector for 30 seconds.
Tap the glass twice, away from the sensor. Wait at least 10
seconds before testing again.
Press and hold the test button until the system sounds
transmission beeps.
Press and hold the appropriate help button until the light blinks
and the panel sounds for at least seven beeps.
Press and hold the Lock and Unlock buttons simultaneously for 3
seconds.
For sensor testing a 1.0 touch screen, press and hold the
Emergency button for 5 seconds.
For sensor testing a 1.1 or greater touch screen, press the
Settings (the gear) button, scroll down, and then press the RF Test
button.
Press and hold the two Emergency buttons simultaneously for 3
seconds
Press and hold the two Emergency buttons simultaneously for 3
seconds.
45