Timers - GE Simon XT Installation Manual

Hide thumbs Also See for Simon XT:
Table of Contents

Advertisement

Table 17: Communication modes
Function
Default
Phone 1 report
Off
mode
Phone 2 report
Off
mode
Phone 3 report
Off
mode
Phone 4 report
Off
mode
Alarms include: Fire, Intrusion, Emergency, Silent, and Alarm Cancels.
Nonalarms include: Latchkey, No Activity, Openings, Closings, Fail-to-Open, Fail-to-
Close, Force Armed, AC Power Failure, CPU Low Battery, and Trouble Restoral.

Timers

Table 18 below describes the Timers menu.
Table 18: Timers menu
Function
Default
Latchkey time
Off
Entry delay
030 seconds
Exit delay
060 seconds
No activity tm
Off
Simon XT Installation Manual
Description
Determines how the panel sends a report to the central station
for each of the phone numbers programmed.
The options are: All SIA, All CID, Alarm SIA, Alarm CID, Nonalarm
SIA, Nonalarm CID, backup SIA (phone failure backup), Backup
CID (phone failure backup), Voice dialer, Off
Description
Determines whether the panel reports a latchkey alarm if the
system is not disarmed at a preset time between midnight and
11:59 p.m. (on). If the latchkey feature is disabled (off), the panel
will not report a latchkey alarm. The system clock must be set
for the latchkey feature to work.
Determines how much time you have to disarm the system
after entering the armed premises through a designated delay
door, before an alarm occurs. Beeps sound during the entire
delay time to remind you to disarm the system. When turned
on, the entry delay can be set from 030 to 240 seconds.
Determines how much time you have to leave the premises
through a designated delay door after arming the system.
Beeps sound after arming the system to remind you to leave
the armed premises. If a delay door is opened after the exit
delay expires, the entry delay begins. If you arm the system
with no delay and open a delay door after the exit delay
expires, an alarm occurs.
Determines whether the panel sends a no activity report to a
central station when the programmed time elapses (on), or if
the feature is disabled (off). No activity means the control
panel, remote handheld, and key-chain touchpad buttons have
not been pressed and sensors have not been tripped within a
specified time (except sensors in group 25 and 43). The timeout
can be set from 02 to 24 hours.
35