Name/application
24
Local instant auxiliary: 24-hour local alarm zone
protecting anything that opens and closes. Sirens shut
off at restoral. No report.
25
Local special chime: Notify the user when a door is
opened.
26
Fire: 24-hour fire, rate-of-rise heat, and smoke sensor.
27
Lamp control or other customer feature. No report.
28
PIR motion sensor, sound sensor, or pressure mat. RF
thermostat. No report
29
Auxiliary: Freeze sensor.
32
PIR motion sensor or sound sensor. No report.
34
Carbon monoxide alarm.
35
Entry/exit delay interior PIR motion
36
Special intrusion: Such as gun cabinets and wall safes.
Reports as tamper if tripped.
38
Auxiliary: Water sensor.
39
Local instant interior: 24-hour local alarm zone
protecting anything that opens and closes. No report.
40
Local special chime.
43
Property/asset management: Notify the user that a
protected asset has moved.
Note: We recommend you use this sensor group in
combination with a Two-Way Talking Touch Screen.
Simon XT Installation Manual
Siren type
Emergency
I
Y
Y
Three beeps
I
N
Y
Fire
I
Y
Y
Silent
I
Y
Y
Silent
I
N
Y
Trouble
I
Y
Y
beeps
Silent
I
N
N
Emergency
I
Y
Y
Intrusion
S
N
Y
Intrusion
I
Y
Y
Trouble
I
Y
Y
beeps
Intrusion
I
Y
Y
Three beeps
I
Y
Y
One beep
I
N
Y
Active in
arming
levels
01234
01234
01234
01234
01234
01234
01234
01234
234
1234
01234
1234
01234
01234