WSW46
Selector
No.
1
Monitoring the PC ON/OFF state
2
Parallel port output pins kept at high
3
level
4
|
Not used.
8
NOTE: Selector 3 is applicable only to models equipped with a parallel interface.
Selectors 1 and 2: Monitoring the PC ON/OFF state
l
For the related functions, refer to WSW36, selectors 2 and 3.
Selector 3: Parallel port output pins kept at high level
l
Setting this selector to "0" will keep all parallel output pints of the facsimile equipment at high
level. Use this setting if Resource Manager (bundled with MFC models) installed to WindowsNT
running on the connected PC fails to monitor the power ON/OFF state of the facsimile equipment.
(Monitor of power ON/OFF state and parallel port kept at high)
Function
46
Setting and Specifications
No. 1 2
0 0 : Disabled
0 1 : Monitor SELECT IN
1 0 : Monitor STROBE
1 1 :
Monitor both SELECT IN and
STROBE