4) Now remove the container and perform the screening operation.
5) Then put the same 500ml container back on to the scale. The scale will show 0.0g
on the display.
6) Add the screenings to the container, the display shows the weight of the screenings.
For this example say 30.0g
g
7) Once the stable light has shown on the display press the [S/P CE]. The balance
will show Store 2 for 2 seconds and then "xx.x Kg / Hl". If the screenings were
30.0g then in this example it would show 6.00 Kg/Hl.
The Store symbol (►) lights up when the second net weight is stored and the Kg/Hl
symbol (►) also lights up.
8) To determine the percentage of screenings to the initial grain press the [S/P CE]
key again.
seconds and then " XX.X PER". In the example the 1
( calculated as 80.00Kg/Hl), the 2
Therefore the percentage value would be 7.50%.