Electrical Requirements - KitchenAid KBSU487TSS Installation Instructions And Use & Care Manual

Built-in insulated jacket grills
Hide thumbs Also See for KBSU487TSS:
Table of Contents

Advertisement

Available languages

Available languages

Warming Drawer Size
24" (61.0 cm)
*Dimension L is the minimum mounting surface area around the opening for mounting the optional door or drawers.
Built-in Outdoor Grill Enclosure Ventilation for LP Gas:
An enclosure for an LP gas fuel tank is to be ventilated by
openings at both the top and lower levels of the enclosure.
If converting to LP gas these vents are to be in the enclosure:
An enclosure for use with an LP gas fuel tank for built-in
installation is to have at least one ventilation opening on an
exposed exterior side located within 5" (12.7 cm) of the top is to
be a minimum of 20 in.
2
(129.0 cm
within 1" (2.5 cm) of the bottom of the enclosure and the bottom
opening is to be a minimum of 10 in.
openings are to be unobstructed. Every opening is to be a
minimum of
" (0.32 cm) wide.
2
2
20 in.
(129.0 cm
) min.
ventilation both sides
1" (2.5 cm) max.
2
2
10 in.
(64.5 cm
) min.
ventilation both sides
8
Cutout Dimensions - Outdoor Refrigerator
Dimension G
24" (61.0 cm)
Cutout Dimensions - Outdoor Ice Maker
Dimension G
18" (45.7 cm)
Cutout Dimensions - Built-in Warming Drawer
Dimension J
22½" (57.2 cm)
Cutout Dimensions - Built-in Utility Drawer and Built-in Trash Drawer
Dimension M
12¼" (31.1 cm)
2
). One ventilation opening
2
(64.5 cm
2
). All vent
5" (12.7 cm) max.
5" (12.7 cm) max.
Dimension H
35¼" (89.5 cm)
Dimension H
34" (86.4 cm) min. to 34½" (87.6 cm) max.
Dimension L*
1½" (3.8 cm)

Electrical Requirements

WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine that the
ground path is adequate.
Check with a qualified electrician if you are not sure whether the
grill is properly grounded.
A 120-volt, 60-Hz, AC-only, 15-amp, fused electrical supply is
required.
It is recommended that a separate circuit servicing only this grill
be provided.