Burner Requirements for High Altitude
Input ratings shown on the model/serial rating plate are for
elevations up to 2,000 ft (609.6 m).
For elevations above 2,000 ft (609.6 m), ratings are reduced at a
rate of 4% for each 1,000 ft (304.8 m) above sea level. Orifice
conversion is required for elevations above 2,000 ft (609.6 m).
See "Assistance or Service" section to order High Altitude
Conversion Kit.
Gas Supply Line Pressure Testing
Testing above ½ psi (3.5 kPa) or 14" (35.5 cm) WCP (gauge):
The grill and its individual shutoff valve must be disconnected
from the gas supply piping system during any pressure testing of
that system at test pressures greater than ½ psig (3.5 kPa).
Testing below ½ psi (3.5 kPa) or 14" (35.5 cm) WCP (gauge) or
lower:
The grill must be isolated from the gas supply piping system by
closing its individual manual shutoff valve during any pressure
testing of the gas supply piping system at test pressures equal to
or less than ½ psig (3.5 kPa).

Gas Connection Requirements

Natural Gas
Built-in grill models are equipped for use with Natural gas. They
are design-certified by CSA International for LP (propane) gases
with appropriate conversion.
Built-in models are set for Natural gas use and have a pressure
regulator with ½" female pipe threads.
A
A. Grill gas pipe
B. New CSA International approved
"outdoor" flexible gas supply line
C. Rear of grill
D. To Natural gas supply
10
B
C
D
The supply line shall be equipped with an approved shutoff valve.
This valve should be located in the same area as the grill and
should be in a location that allows ease of opening and closing.
Do not block access to the shutoff valve. The valve is for turning
on or shutting off gas to the grill.
A
A. Gas supply line
B. Shutoff valve "open" position
C. To grill
LP Gas Conversion Using a Local LP Gas Supply
Conversion must be made by a qualified person. The installation
of this grill must conform with local codes or, in the absence of
local codes, with either the National Fuel Gas Code, ANSI
Z223.1/NPFA 54, Natural Gas and Propane Installation Code,
CSA B149.1, or Propane Storage and Handling Code, B149.2.
To convert to LP gas, the LP Gas Conversion Kit Part Number
W10118099 must be used. Follow instructions included with kit.
A
A. Grill gas pipe
B. New CSA International approved
"outdoor" flexible gas supply line
C. Rear of grill
D. To local LP gas supply
LP Gas Conversion Using a 20 lb LP Gas Fuel Tank
To convert to LP gas, the LP Gas Conversion Kit Part Number
W10118099 must be used. Follow instructions included with kit.
A 20 lb LP gas fuel tank must be purchased separately.
B
C
B
C
D