INSTALLATION
7a. Basic or FireGenie remote : Attach the other black wire from the
remote receiver to TH on the valve, see Diagram 7.
7b. GT remote control: Attach the green wire from the wiring harness
labeled TH and attach wire to TH on the valve, see Diagram 7.
Diagram 7
8. Tuck all wires neatly into base of the unit.
9. Locate the red and black ON/OFF switch wires from the appliance,
see Diagram 8.
10. Locate the ON/OFF switch, packed in the manual package.
11. Connect ON/OFF switch wires to ON/OFF switch, see Diagram 9.
Empty terminal
Diagram 9
46
ON/OFF switch wires
Diagram 8
ON/OFF switch wires
12. Snap ON/OFF switch into position.
Note: Ensure when snapped into position—the empty
terminal on the back side of the switch is facing upward, see Diagram 9.
13. Code remote control. See remote control manual for coding instruc-
tions and battery installation.
Important Note: When remote control is coded, ensure that the ON/OFF
switch is in the on position or facing up and the remote
receiver is in the remote position.
FAN WIRING
ROTARY SPEED CONTROL
GREEN
WHITE
TO TH - TP
VALVE WIRING
ON VALVE
TO TH
ON VALVE
F/M
RED
F=Female
M=Male
REMOTE CONTROL/WALL THERMOSTAT
CAUTION: Label all wires prior
to disconnection when servicing
controls. Wiring errors can
cause improper and dangerous
operation.
WARNING: Electrical Grounding Instructions
This appliance is equipped with a three pronged
(grounding) plug for your protection against shock
hazard and should be plugged directly into a prop-
erly grounded three-prong receptacle. Do not cut
or remove the grounding prong from this plug.
BLACK
THERMODISC
WHITE
HI LIMIT
BLACK
SWITCH
2 WAY
SWITCH
BLACK
BLACK
SPILL
SWITCH