Regency E21-LP2 Owners & Installation Manual

E21 series gas insert

Advertisement

WARNING:
If the information in these instructions are not followed exactly,
a fi re or explosion may result causing property damage,
personal injury or loss of life.
FOR YOUR SAFETY
Do not store or use gasoline or other fl ammable vapors and
liquids in the vicinity of this or any other appliance.
Installation and service must be performed by a qualifi ed
installer, service agency or the gas supplier.
Tested by:
918-510
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
E21 Gas Insert
MODELS: E21-NG2 Natural Gas E21-LP2 Propane
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
www.regency-fi re.com
Owners &
Installation Manual
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appliance
Do not touch any electrical switch:
do not use any phone in your
building.
Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
If you
cannot reach your gas
supplier, call the fi re department.
07/17/06

Advertisement

Table of Contents
loading

Summary of Contents for Regency E21-LP2

  • Page 1 Owners & E21 Gas Insert Installation Manual MODELS: E21-NG2 Natural Gas E21-LP2 Propane WARNING: FOR YOUR SAFETY If the information in these instructions are not followed exactly, What to do if you smell gas: a fi re or explosion may result causing property damage, Do not try to light any appliance personal injury or loss of life.
  • Page 2 Gas Fireplace Series has been designed to provide you with all the warmth and charm of a fi replace, at the fl ick of a switch. The models E21-NG2 and E21-LP2 of this series have been approved by Warnock Hersey for safety. As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow.
  • Page 3: Table Of Contents

    Flush Glass ..............15 Flush Louvers ..............16 Optional Bay Front ............16 Bay Louvers ..............16 Conversion Kit# 534-969 from NG to LP .....17 Full Screen doors ............20 Remote Control ............22 Wall Switch ..............22 Wall Thermostat ............22 ® Regency E21-2 Gas Fireplace Insert...
  • Page 4: Safety Label

    SAFETY LABEL This is a copy of the label that accompanies Note: Regency ® units are constantly being each Regency ® Gas Insert. We have printed improved. Check the label on the unit a copy of the contents here for your review.
  • Page 5: Requirements

    (e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation. ® Regency E21-2 Gas Fireplace Insert...
  • Page 6: Installation

    AS THE APPLIANCE. 12) Wear gloves and safety glasses for protection while doing required maintenance. ® The Regency Gas Fireplace must be installed C L O T H I N G O T H E R in accordance with these instructions. Carefully...
  • Page 7: Policy For Solid Fuel Burning & Factory Built Fireplaces

    CLEARANCES FACTORY BUILT 1) Locate your appliance. Refer to the "Clear- Diagram shows the minimum fi replace opening ances to Combustibles" and "Minimum required to be able to install the Regency ® FIREPLACES Fireplace Clearances" sections. fi replace insert. ®...
  • Page 8: Clearances To Combustibles

    14 inches (356mm). The minimum combustible board. height from the top of the louver to the ceiling is 36 inches (914mm). aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa ® Regency E21-2 Gas Fireplace Insert...
  • Page 9: Gas Connection

    Propane: 0-4500 ft. existing chimney system, thoroughly clean this appliance. the masonry fi replace that has been chosen for the Regency ® Gas Fireplace. Burner Inlet Orifi ce Sizes: The gas connection is a 3/8" NPT accessible on Natural Gas Propane the left side of the unit.
  • Page 10: Wiring Diagrams

    (grounding) plug for cause improper and dangerous your protection against shock hazard operation. and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug. ® Regency E21-2 Gas Fireplace Insert...
  • Page 11: Flue Connector Installation

    4) Replace the screw holding the plate just before completely pushing the appliance into the fi replace. Note: Do not operate unit if fl ue connector is not fastened in original position. ® Regency E21-2 Gas Fireplace Insert...
  • Page 12: Gas Pipe Pressure Testing

    fi replaces. and ventilation air available to the room in The Regency ® Insert incorporates its own which it is to be operating. internal draft hood, so no additional external draft hood is required.
  • Page 13: Valve Description

    fi rst (see diagram for correct Note: Aeration Adjustment should only be positioning), then the two side panels. Slide performed by an authorized Regency ® the side brick panel into place from the front Installer at the time of installation or of the fi...
  • Page 14: Log Set Installation

    1. Hint: Don't tighten the trim to p u s h the bottom of the faceplate side panels with down. the screws provided. See diagram 1. ® Regency E21-2 Gas Fireplace Insert...
  • Page 15: Flush Glass

    6) Connect the ON/OFF switch wires by taking the black and red wires with the female panel(s) should be done by a qualifi ed ends and connecting them to the ON/OFF service person. Diagram 5 switch. ® Regency E21-2 Gas Fireplace Insert...
  • Page 16: Flush Louvers

    2 screws into the bracket on the bottom of the Bay Front as per diagram 1. NOTE: The top and bottom trim pieces are different. ® Regency E21-2 Gas Fireplace Insert...
  • Page 17: Conversion Kit# 534-969 From Ng To Lp

    Turn the unit off and allow it to cool to room temperature. Shut off glass supply Unplug or disconnect power source to stove. Remove glass front (see Door Glass Fig.2 Replacement section in the manual). Remove logs and brick panels (if installed). ® Regency E21-2 Gas Fireplace Insert...
  • Page 18: Installation Of The Dc Sparker

    23) Replace the yellow "NG" label with red "LPG" label. Fig.5 Installation of the DC Sparker: 18) Re-assemble the black protection cap (Fig. 6). 24) Locate the Piezo Ignitor situated at the side of valve. Piezo Ignitor Fig. 6 ® Regency E21-2 Gas Fireplace Insert...
  • Page 19 37a) Find a location which is not too hot and These instructions must is easy to reach for changing the battery. be left with the appliance. Note: It should be kept away from the chain. ® Regency E21-2 Gas Fireplace Insert...
  • Page 20: Full Screen Doors

    It is held in place by magnets. 2) Lift the unit up slightly and push down on the corners of the Bottom Trim Bracket and slide under unit. Screw Push in Corners Top Frame Bottom Trim Bracket ® Regency E21-2 Gas Fireplace Insert...
  • Page 21 Hold the door at a 45 degree angle to avoid scratching the faceplate. Hinge 6) Place Bottom Frame near hinge. Flip hinge over Bottom Frame and secure with 3 screws each. Screen Door Hinge Location Bottom Frame 8) Close screen doors. ® Regency E21-2 Gas Fireplace Insert...
  • Page 22: Remote Control

    REMOTE CONTROL WALL SWITCH WALL THERMOSTAT Use the Regency Remote Control Kit approved 1) Run the wire through the right or left side A wall thermostat may be installed if desired, for this unit. Use of other systems may void inlet opening.
  • Page 23: Operating Instructions

    WITHOUT THE GLASS FRONT IN the gas control knob. The pilot fl ame should PLACE. continue to burn. If the pilot does not remain lit, repeat operation allowing a longer period before releasing gas control knob. ® Regency E21-2 Gas Fireplace Insert...
  • Page 24: Copy Of Lighting Plate Instructions

    OPERATING INSTRUCTIONS COPY OF LIGHTING PLATE INSTRUCTIONS LIGHTING INSTRUCTIONS Gas Inlet TO TURN OFF GAS APPLIANCE ® Regency E21-2 Gas Fireplace Insert...
  • Page 25: Automatic Convection Fan Operation

    If you have an incorrect fl ame pattern, operation of a gas regulator or valve. unit on. If the top louvers start to discolour, ® contact your Regency dealer for further check the door gasket seal and replace if instructions.
  • Page 26: Removing Valve Assembly

    REMOVING VALVE fi rebox bottom and 4 screws on the rear REPLACEMENT ASSEMBLY wall., and lift out. Your Regency ® stove is supplied with high 1) Disconnect the power. temperature, 5 mm Neoceram ceramic glass that will withstand the highest heat that your unit will 2) Shut off the gas.
  • Page 27: Parts List

    530-952 Bay Louver (set)-Black 530-954 Bay Louver (set)-Gold/Black 530-955 Bay Louver (set)-Steel/Black BR I C K PAN EL SET FR O N TS PLEASE R EFER SEPAR ATE I LLU STR ATI O N ® Regency E21-2 Gas Fireplace Insert...
  • Page 28: Burner Assembly & Log Set

    Electrode 904-162 #43 Orifi ce (NG) 904-163 #54 Orifi ce (LP) 402-526 Grate/Diffuse Assembly 532-530 Burner Assembly - NG/LP 532-930 Complete Log Set 534-969 Conversion to Propane Kit *Not available as a replacement part. ® Regency E21-2 Gas Fireplace Insert...
  • Page 29: Bay & Flush Front Assembly

    Bay Glass Trim Bottom - Black 402-956 Gold Trim Bay Front 402-958 Steel Trim Bay Front 114) Glass Retainer - Side - Top & Bottom 115) Glass Retainer - Center - Top & Bottom ® Regency E21-2 Gas Fireplace Insert...
  • Page 30: Faceplate Assembly

    402-918 Faceplate & Trim (Set) - Zero Clearance Kit-Contour 532-927 Custom Faceplate 190) * Screw - #8 x 1/2" Black Self Tapping 199) 948-216 Regency ® Logo 532-940 Full Screen Doors - Black 532-942 Full Screen Doors - Nickel 532-943 Full Screen Doors - Copper *Not available as a replacement part.
  • Page 31: Warranty

    FPI will not be liable for acts of God, or acts of terrorism, which cause malfunction of the appliance. Performance problems due to operator error will not be covered by this warranty policy. Products made or provided by other manufacturers and used in conjunction with the operation of this appliance without prior authorization from Regency ®...
  • Page 32 Fireplace Products International Ltd. is pleased to extend this Limited Lifetime Warranty to the ® original purchaser of a Regency Product. See the inside back cover for details. Register your Regency ® online at http://www.regency-fi...

This manual is also suitable for:

E21-ng2

Table of Contents