E18 series gas insert

Advertisement

* Only available in British Columbia to accredited dealers.
Model
Fuel Type
Natural Gas
Minimum Supply Pressure
(1.25 kPa)
Manifold Pressure - High
(0.87 kPa)
Manifold Pressure - Low
(0.40 kPa)
Orifice Size
Minimum Input
Altitude 0-4500 ft.
15,000 BTU/h (4.40 kW)
(0-1372m)
Maximum Input
Altitude 0-4500 ft.
21,600 BTU/h (6.33kW)
(0-1372m)
Verify the model of the E18 will replace
is one of the following approved units:
Montigo EP28-2
Montigo EP28-4
Montigo EP28-5
Montigo Econo Plus 28C
Montigo EP28-S2
Montigo 36SR (Non powervent unit)
Montigo 28F-2
Montigo 28-F
Firesong 220N
Firesong 120N
E18* Gas Insert
E18-NG
E18-LP
Propane Gas
5" W.C.
12" W.C.
(2.99 kPa)
3.5" W.C.
10" W.C.
(2.49 kPa)
1.6" W.C.
6.4" W.C.
(1.60 kPa)
#44 DMS
#55 DMS
17,000 BTU/h (4.98kW)
20,500 BTU/h (6.01 kW)
23 9/16"
598mm
7 1/4"
184mm
11"
280mm
29 7/16"
747mm
1 15/16"
50mm
34 7/16"
875mm
16 5/8"
423mm
14 9/16"
370mm
3 15/16"
100mm
13 3/4"
349mm
23 15/16"
608mm

Advertisement

loading

Summary of Contents for Regency E18-NG

  • Page 1 E18* Gas Insert * Only available in British Columbia to accredited dealers. Model E18-NG E18-LP Fuel Type Natural Gas Propane Gas 5” W.C. 12” W.C. Minimum Supply Pressure (1.25 kPa) (2.99 kPa) 3.5” W.C. 10” W.C. Manifold Pressure - High (0.87 kPa)
  • Page 2 E18 Gas Insert MINIMUM FIREPLACE CLEARANCES TO COMBUSTIBLES Diagram shows the minimum clearances to any combustible material. Installer must check that all installs maintain at least these clearances.. The minimum clearance from the side of the appliance to a combustible side wall is 6"...
  • Page 3: Zero Clearance Framing

    E18 Gas Insert ZERO CLEARANCE FRAMING 1. When installing the E18 as a Zero clearance, you will use the framing clearances in the 8 3/4" 3 3/4" following diagrams. Mantel 222mm 95mm and inside corner clearances can be found in Minimum Clearances to Combustibles.

This manual is also suitable for:

E18-lp