4. Installation site

Make sure not to under exceed any safety distances. The fireplace should be sited with the appliance
door no less than 1 meter away from combustial materials. When mounting steel chimney on top of
the fireplace we refer to the assembly manual from the respective chimney manufacturer. Comply with
the safety distances that are required when mounting a steel chimney.
The fireplace insert model and the concrete surrounding determines height on firewall. The distance
between smoke pipe and flammable wall & construction must be at least 300 mm. The shortest dis-
tance between upper air outlets or top of concrete surrounding must be at least 380 mm.
Placed in corner
20
Firewall rim mounted on wall - corner
Minimum
firewall width
N-21
N-24
Firewall flush mounted - corner
Minimum
firewall width
N-21
N-24
All measures are approximately as misalignment in wall and floor, and distance
8
550
575
760
820
to centre of smoke inlet into chimney can vary.
Placed on straight wall
20
Firewall rim monted on wall - straight wall
Minimum
firewall width
N-21
N-24
Firewall flush mounted - straight wall
Minimum
firewall width
N-21
N-24
700
750
1020
1070