Ventilation Air From Inside Building; Ventilation Air From Outdoors - Kingsman ZVFB2410MVN Owner's Operation And Installation Manual

Unvented (vent-free) firebox
Table of Contents

Advertisement

AIR FOR COMBUSTION AND VENTILATION Cont.

VENTILATION AIR FROM INSIDE BUILDING

This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you
must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting
the two spaces. You can also remove door into adjoining room. Follow the National Fuel Gas Code NFPA 54/ANSI Z223.1,
Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

Ventilation Air From Outdoors

Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent openings: one within 12" of the
ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These
spaces include attics and crawl spaces.
IMPORTANT: Do not provide openings for inlet or outlet air into attic if attic has a thermostat-controlled power vent.
Heated air entering the attic will activate the power vent.
FIGURE 5 - Ventilation Air from Inside Building
WARNING
Rework worksheet, adding the space of the adjoining
unconfined space. The combined spaces must have
enough fresh air to supply all appliances in both spaces.
FIGURE 6 - Ventilation Air from Outdoors
9