QUADRA-FIRE 2100 & 4300 MILLENIUM ACC WOOD BURNER INSTALLATION INSTRUCTIONS
QUADRA-FIRE 2100 & 4300 MILLENIUM ACC WOOD BURNER INSTALLATION INSTRUCTIONS
IMPORTANT: Read all instructions carefully before starting installation. Failure to follow these
instructions may result in a fi re hazard and will void the warranty.
Fig. 3,4,5 and Table 1 & 2 relate to installations with tested fl ue systems; as per AS/NZS 2918:2001 -
Appendix F, with a ceiling angle between 0° - 30° inclusive.
For installations with a ceiling angle greater than 30°, refer to Fig. 6 & 7 and AS/NZS 2918:2001 4.6.3(b)
Ceiling Plate may vary in size depending on ceiling angle. Please specify ceiling pitch prior to ordering the
ceiling plate.
Quadra-Fire 2100 & 4300 Millenium ACC wood burner's are tested and approved to the N.Z. National
Environmental Standards;
Softwood Particulate Emissions = 0.4 g/kg Space Heating Effi ciency = 71%
Hardwood Particulate Emissions = 2.5g/kg Space Heating Effi ciency = 78%
www.quadrafi re.com
INSTALLATIONS TO COMPLY WITH AS/NZS2918:2001
AND WILL REQUIRE A BUILDING CONSENT
21M-ACC-NZ - 2100 Millenium ACC Softwood Certifi ed
Particulate Emissions = 0.6 g/kg Space Heating Effi ciency = 72%
21M-ACC-AU - 2100 Millenium ACC Hardwood Certifi ed
Particulate Emissions = 2.0 g/kg Space Heating Effi ciency = 81%
43M-ACC-NZ - 4300 Millenium ACC
21M-ACC-NZ
21M-ACC-AU
43M-ACC-NZ
7037-141D
Model:
October 12. 2015

Advertisement

Table of Contents
loading

Summary of Contents for Quadra-Fire 21M-ACC-NZ

  • Page 1 Ceiling Plate may vary in size depending on ceiling angle. Please specify ceiling pitch prior to ordering the ceiling plate. • Quadra-Fire 2100 & 4300 Millenium ACC wood burner’s are tested and approved to the N.Z. National Environmental Standards; 21M-ACC-NZ - 2100 Millenium ACC Softwood Certifi ed Particulate Emissions = 0.6 g/kg Space Heating Effi...
  • Page 2 PERFORMANCE MAY VARY FROM TEST VALUES DEPENDING ON ACTUAL OPERATING CONDITIONS. INSTALLATION U.S. ENVIRONMENTAL PROTECTION AGENCY 7037-147B DATE Export stove. May not be operated within the United States. Fig. 2 - Quadra-Fire 4300 Millenium ACC Wood Burner Dimensions 660mm 729mm 668mm 247mm 330mm 170mm...
  • Page 3 PERFORMANCE MAY VARY FROM TEST VALUES DEPENDING ON ACTUAL OPERATING CONDITIONS. INSTALLATION U.S. ENVIRONMENTAL PROTECTION AGENCY 7039-148B DATE Export stove. May not be operated within the United States. Fig. 1 - Quadra-Fire 2100 Millenium ACC Wood Burner Dimensions 594mm 671mm 618mm 219mm 297mm 170mm...
  • Page 4: Floor Protector

    2100 & 4300 Millennium ACC Wood Burner FLOOR PROTECTOR 1.QF.1B Quadra-fire 2100 & 4300 Millennium ACC do not require a insulating Floor Protector, as they are tested and comply with the minimum Floor Protector requirements of AS/NZS 2918:2001. Note: The minimum Floor Protector sizes are specified in the clearance chart, see Table 1 & 2.
  • Page 5: Firebox Installation

    2100 & 4300 Millennium ACC Wood Burner CORNER POSITIONING (45°) CORNER POSITIONING (45˚) 1.QF.1C Fig. 4 Table 2 With Double Flue DESCRIPTION DESCRIPTION With Double Flue Shield Fitted Shield Fitted Pioneer Double Flue Mounted Shield Universal Pioneer Double Flue Mounted Shield Universal Shall be Fitted 2100 4300...
  • Page 6: General Instructions For Flue System

    2100 & 4300 Millennium ACC Wood Burner GENERAL INSTRUCTIONS FOR FLUE SYSTEM 1.QF.1D Flue pipe installed crimp/narrow end down Outer casings installed crimped/narrow end up. (Critical when exposed above the roof) Inner casings - direction not critical Flue pipes - seal all joints including firebox spigot. - fix with a minimum of 3 stainless steel rivets Flue pipe spacers - affix to flue pipe Flue system termination point - Refer to AS/NZS 2918:2001 4.9.1, see Fig.
  • Page 7 Promina board or similar under the flashing Approved Flashing Roof Line Inner Casing 200mm above roof line Outer Casing Inner Casing Internal Swage 12.5 Vented Ceiling Plate Pioneer Double Flue Shield Flue Pipe Quadra-fire Millennium Floor Protector Page 7 October 12, 2015 7037-141D...
  • Page 8 2100 & 4300 Millennium ACC Wood Burner FLUE PENETRATION 1.QF.1F Un-tested flue systems, as per AS/NZS 2918:2001, 4.6.3(b) ADD Cowl Fig. 6 AS/NZS2918:2001 Casing Cover Un-tested flue with sloped ceiling Spider Bracket penetration greater than 30° from horizontal A = 25mm Approved Flashing 4.6.3(b) Fig 4.6 = downward distance of...
  • Page 9: Minimum Height Of Flue System Exit

    2100 & 4300 Millennium ACC Wood Burner PIONEER DOUBLE FLUE SHIELD FITTING INSTRUCTIONS 1.QF.1G 1. Unpack the Flue Mounted Shield, detach the three brackets and familarize yourself with the illustrations. 2. Using a sharp knife or razor blade, carefully cut through the plastic film on the “inside face” where it meets the outer shield (refer sketch).
  • Page 10 2100 & 4300 Millennium ACC Wood Burner AS/NZS 2918:2001 General Notes 1.QF.1H WARNINGS: WARNING: THE APPLIANCE AND FLUE SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH AS/NZS 2918 AND THE APPROPRIATE REQUIREMENTS OF THE RELEVANT BUILDING CODE OR CODES. WARNING: APPLIANCES INSTALLED IN ACCORDANCE WITH THIS STANDARD SHALL COMPLY WITH THE REQUIREMENTS OF AS/NZS 4013 WHERE REQUIRED BY THE REGULATORY AUTHORITY, I.E.
  • Page 11: Service And Maintenance Log

    2100 & 4300 Millennium ACC Wood Burner Service And Maintenance Log Date of Service Performed By Description of Service Page 11 October 12, 2015 7037-141D...
  • Page 12 2100 & 4300 Millennium ACC Wood Burner AUSTRALIAN WARRANTY INFORMATION Hearth & Home Technologies Inc (HHT) 1445 N. Highway | Colville, WA 99114 | (509-684-3745) HHT extends the following manufacturer’s warranty for HHT gas, wood, pellet, coal and electric hearth appliances that are purchased from an HHT authorized dealer.
  • Page 13 2100 & 4300 Millennium ACC Wood Burner OTHER RIGHTS The HHT manufacturer’s warranty is in addition to other rights and remedies that you may have under Australian law. Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage.
  • Page 14: Homeowner's Notes

    2100 & 4300 Millennium ACC Wood Burner Homeowner’s Notes Page 14 7037-141D October 12, 2015...
  • Page 15: Service Parts

    2100 & 4300 Millennium ACC Wood Burner 21M-ACC-AU, 21M-ACC-NZ Service Parts 2100 Millennium Wood Stove Beginning Manufacturing Date: July 2012 Advanced Combustion Control (ACC) Ending Manufacturing Date: Active Part number list on following pages. Page 15 October 12, 2015 7037-141D...
  • Page 16 2100 & 4300 Millennium ACC Wood Burner 21M-ACC-AU, 21M-ACC-NZ Service Parts Beginning Manufacturing Date: July 2012 Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your appliance please provide model number and serial number. All parts listed Stocked in this manual may be ordered from an authorized dealer.
  • Page 17 2100 & 4300 Millennium ACC Wood Burner 21M-ACC-AU, 21M-ACC-NZ Service Parts Beginning Manufacturing Date: July 2012 Ending Manufacturing Date: Active #17 Door Assembly #18 Baf e Protection Channel # 16 Burn Rate Control Assembly Side view Front, looking into unit 16.10...
  • Page 18 2100 & 4300 Millennium ACC Wood Burner 21M-ACC-AU, 21M-ACC-NZ Service Parts Beginning Manufacturing Date: July 2012 Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement Stocked parts for your appliance please provide model number and serial number. All parts listed in this manual may be ordered from an authorized dealer.
  • Page 19 2100 & 4300 Millennium ACC Wood Burner 43M-ACC-NZ Service Parts Wood Stove Beginning Manufacturing Date: July 2009 Ending Manufacturing Date: Active 43M-ACC-NZ Part number list on following page. Page 19 October 12, 2015 7037-141D...
  • Page 20 2100 & 4300 Millennium ACC Wood Burner 43M-ACC-NZ Service Parts Beginning Manufacturing Date: July 2009 Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION . Parts must be ordered from a dealer or Stocked Hearth and Home Technologies does not sell directly to consumers distributor.
  • Page 21 2100 & 4300 Millennium ACC Wood Burner 43M-ACC-NZ Service Parts Beginning Manufacturing Date: July 2009 Ending Manufacturing Date: Active #17 Pedestal Assembly #16 Brick Set Assembly 16.1 16.1 17.1 16.1 16.1 16.5 16.1 16.1 16.1 16.1 16.1 16.1 17.2 16.1 16.1 16.4 16.5...
  • Page 22 2100 & 4300 Millennium ACC Wood Burner 43M-ACC-NZ Service Parts Beginning Manufacturing Date: July 2009 Ending Manufacturing Date: Active #18 Door Assembly 18.1 18.2 18.6 18.5 18.3 18.4 IMPORTANT: THIS IS DATED INFORMATION . Parts must be ordered from a dealer or Stocked Hearth and Home Technologies does not sell directly to consumers distributor.
  • Page 23: Side View

    SRV7033-298 Component Pack (Includes Spring Handles (1) 1/2 Inch & (2) SRV7037-019 1/4 Inch, Trimount Plug, Owners Manual) Gasket, Manifold Pkg of 4 7038-168/4 Logo, Quadra-Fire Nickel 200-3240 Outside Air Kit, Floor & Rear OAK-ACC Outside Air Collar Assembly 7033-039...
  • Page 24 Please contact your Quadra-Fire dealer with any questions or concerns. For the number of your nearest Quadra-Fire dealer logo onto www.quadrafi re.com CAUTION DO NOT DISCARD THIS MANUAL Read, understand and Leave this manual with • • • Important operating and...

This manual is also suitable for:

21m-acc-au43m-acc-nz

Table of Contents