3. Fuel System
Simpo PDF Merge and Split Unregistered Version - http://www.simpopdf.com
Fuel level inspection
Caution
Check the float valve and float for proper
installation.
To get the correct reading, position the fuel
level gauge in the way that float chamber
face is vertical to the main jet.
Fuel level:10.2mm
Assemble the fuel cup after confirming the fuel
level.
C arburetor Installation
6 B
Install the carburetor in the reverse order of
removal.
Following adjustments must be made after
installation.
Throttle cable free play adjustment.
Idle speed adjustment
3-10
To this chapter contents
Fuel level gauge
Adjusting nut
2 screws
Locknut