27
PROBLEM
The driven nail is
bent
Nails do not fire
'flush' into the
workpiece.
Nails jam
Note: For further repair information, please call 1-800-689-9928.
POSSIBLE CAUSES
1. Nails are inaccurately fed.
2. Incorrect nails are loaded.
3. Air pressure is too low.
4. Driver blade is worn or
broken.
5. The wood is too hard.
1. The wood is too hard.
2. Air pressure is too low.
3. Drive blade is worn or broken.
4. Incorrect driving depth
adjustment.
1. Piston ring or cylinder is worn,
broken, or dirty.
2. Nails are not feeding into the
chamber properly.
3. Incorrect nails being used.
4. Driver blade tip is worn.
5. Driver guide is damaged or
worn.
6. Workpiece material (or backer)
is too hard.
AIR-POWERED 2-IN-1 NAILER 058-8548-4
SOLUTIONS
1. Remove and load the nails properly.
2. Remove incorrect nails and load the
recommended nails (see section "Technical
specifications.")
3. Adjust the air pressure.
4. Replace the driver blade if it either protrudes
from the blade guide or appears to be
excessively worn.
5. Test fire to determine whether nails bend on
soft wood. If it bends, a higher gauge nailer
is required.
1. Test fire to determine whether nails bend on
softer wood. If it bends, a higher gauge nailer
is required.
2. Adjust the air pressure.
3. Replace the driver blade if it either protrudes
from the blade guide or appears to be
excessively worn.
4. Adjust the depth adjustment dial to the
appropriate position.
1. Send for service.
2. See above items.
3. See above items.
4. Send for service.
5. Inspect and send tool for service.
6. Use an alternate tool.