■ All Reset

When the all reset mode is activated, all of the following set-
tings will be reset to the factory default.
• Administrator password
• PS·Data communication setting
• LCD brightness, contrast, alarm buzzer, and button
buzzer settings
• Button functions and joystick button functions (F1 to F8,
A, B, and top buttons)
• Controller functions
(Time & Date Type)
(Auto Login)
(Operator Setup)
(Function Level)
(Camera Level)
(Cam Posi Map)
(Cam-Unit Map)
(HDD-Unit Map)
(LCD Title)
Note: Calibration settings of panning, tilting, and zooming
will be maintained even after all reset.
● Operation
1. Turn off the power.
Note: If you set the MODE Switch #1 to #4 to ON, you
can skip entering the administrator password in
Step 3.
2. Turn on the power while holding down the buttons
2, 4, and 6.
"Admin Password" will appear on the LCD to enter the
password.
All Reset
Admin Password _____
3. Enter the administrator password.
The password entered will be displayed as "∗" marks.
All Reset
Admin Password ∗ ∗ ∗ ∗ ∗
Notes:
• The factory default is "650".
• To delete a character, press the CLEAR button.
• If you have entered a wrong password, the LCD
display will return to Step 2.
20
4. Press the CAM (SET) button.
If the password entered is correct, all the settings will
be reset to the factory default.
All Reset
All Reset
5. Check "End" on the LCD.
Check "End" has appeared on the LCD to inform you of
the initialization end.
All Reset
6. Turn off the power.
■ PS·Data Communication Setting
This setting is required to establish a connection between
the system units and system controller.
List of PS·Data communication settings
Setting Item Available setting parameter(s)
Baud Rate 4800 / 9600 / 19200 bps
Data Bit
8 bit (Fixed)
Parity Bit
None / Odd / Even
Stop Bit
1 / 2 bit
Wait Time
OFF / 100 msec / 200 msec /
400 msec / 1000 msec
Group Adr A to Z
Xon/Xoff
Not Use (Fixed)
Note: Factory defaults are underlined.
● Operation
1. Turn off the power.
2. Turn on the power while holding down the button 6
and MON (ESC) button.
"Admin Password" will appear on the LCD to enter the
password.
PS Data Com. Setup
Admin Password _____