B) Your dealer may offer a liner fastening system (AC02006), sold separately. Follow the
installation instructions provided with the liner fastening system.

9.4.2 IF THE FLUE LINER DOES NOT ALIGN WITH THE WOOD INBUILT'S FLUE OUTLET

You can install a liner offset adapter (AC01370), which is sold separately. Please note that
an offset adaptor reduces the free flow of exhaust gases and may result in smoke roll-out
from the wood inbuilt when it's door is opened for loading. Only use an offset adaptor if a)
there is no other alternative and b) if the total height of the fireplace and flue system is at
least 20 feet. If you must install a liner offset adapter, secure the three brackets with the
three screws provided (30131) on top of the wood inbuilt in the three holes in front of the
flue outlet. The long end of the brackets must be attached to the wood inbuilt. The
brackets and screws are in the wood inbuilt's owner's manual kit. Then follow the
instructions in the manual provided with the liner offset adapter kit.