Recording - Digital Watchdog Stand-alone DVMR User Manual

8 channel digital video multiplex recorder
Hide thumbs Also See for Stand-alone DVMR:
Table of Contents

Advertisement

8Channel stand-alone DVMR

3-2. Recording

1. PLAY
Changes to Playback Mode from Recording.
If pressed shortly, playback starts from the stop
point in previous operation.
If pressed for a long time, you can enter into GO
TO MENU and select by PERCENT, TIME/DATE,
or EVENT LIST the point from which you want to
replay.
2. MODE
Changes screen division in the sequence of full
screen of specific channel, 4-split screen, and
9-split screen whenever pressed.
If it is pressed for a long time, it changes type of
monitor from COMPOSITE to VGA or VGA to
COMPOSITE in case VGA option board is
included in the DVMR package. In case you
connect CRT type PC monitor to DVMR unit, and
monitor type is set at COMPOSITE, pictures
displayed shall be flickering.
3. P/T
In case you connected PTZ camera to
any channel of DVMR unit, press [P/T] button
first to control this camera using operation
buttons on the front panel.
Be sure to select model of PTZ camera whose
protocol is already incorporated into DVMR
system. Model of PTZ camera whose protocol
incorporated is PELCO D type, DRX-502A.
For PTZ camera whose protocol is not built-in
protocol, you have to input protocol of that
camera in USER DEFINE /PAN/TILT CMD
SEPUP/MISCELLANEOUS SETUP.
After pressing [P/T] button, command with channel
number(from 1 to 8) in front is displayed whenever
you press [LEFT] or [RIGHT] button.
Select channel number first by pressing [UP] or
[DOWN] button, and select command by pressing
[LEFT] or [RIGHT] button.
Then, PTZ camera will move as per command you
selected as far as you press [ENTER] button.
Press [P/T] button once more to stop PTZ camera control.
3. OPeration
ALL ABOUT IMAGE RECOGINITON & PROCESSING
Recording Mode
PAN/TILT Control
(Ex: PELCO D type)
11
8Channel stand-alone DVMR
4-2. Configuration
4-3. RS-232C Hex-codes table
Following ASCII-code are for programmers who want to control DVMR unit via RS-232C port.
RS-232C specification (baud rate/parity/data length/stop bit) : 57600, N, 8, 1
1 Byte ASCII-code.
MODE
PIP
'D'
'I'
FRZ
P/T
'F'
'T'
SEQ
MENU
'Q'
'M'
ENTER
ZOOM
'Z'
4. Configuration
ALL ABOUT IMAGE RECOGINITON & PROCESSING
UP
CH1
'1'
CH5
'5'
CH2
'2'
CH6
'6'
DN
CH3
CH7
'3'
'7'
LEFT
CH4
CH8
'4'
'8'
RIGHT
28
'U'
'J'
'H'
'K'

Advertisement

Table of Contents
loading

Table of Contents