Beep Level - Yaesu FTDX9000MP Operation Manual

Hide thumbs Also See for FTDX9000MP:
Table of Contents

Advertisement

M M M M M
M M M M M
ENU
ENU
ENU
ODE
ODE
ODE
ENU
ENU
ODE
ODE
031. ANT SELECT
Function: Sets the method of antenna selection.
Available Values: BAND/STACK
Default Setting: BAND
BAND: The antenna is selected in accordance with
the operating band.
STACK: The antenna is selected in accordance with
the band stack (different antennas may be
utilized on the same band, if so selected in
the band stack).

032. BEEP LEVEL

Function: Sets the beep level.
Available Values: 0 ~ 255
Default Setting: 50
033. CAT RATE
Function: Sets the transceiver's computer-interface
circuitry for the CAT baud rate to be used.
Available Values: 4800/9600/19200/38400 bps
Default Setting: 4800 bps
034. CAT TIME OUT TIMER
Function: Sets the Time-Out Timer countdown time
for a CAT command input.
Available Values: 10/100/1000/3000 msec
Default Setting: 10 msec
The Time-Out Timer shuts off the CAT data input af-
ter the continuous transmission of the programmed
time.
035. CAT RTS
Function: Enables/Disables the RTS port of the CAT
jack.
Available Values: DISABLE/ENABLE
Default Setting: ENABLE
036. CAT DATA INDICATOR
Function: Enables/Disables the flashing of the Data
LED at the left side of the [ CS ] switch in conjunction
with the CAT commands.
Available Values: DISABLE/ENABLE
Default Setting: ENABLE
037. MEM GROUP
Function: Enables/Disables Memory Group Opera-
tion.
Available Values: DISABLE/ENABLE
Default Setting: DISABLE
039. QUICK SPLIT FREQ
Function: Selects the tuning offset for the Quick Split
feature.
Available Values: –20 ~ 0 ~ +20 kHz (1 kHz Step)
Default Setting: +5 kHz
Page 150
GENERAL G
ROUP
039. TRACKING
Function: Sets the VFO Tracking feature.
Available Values: OFF / BAND / FREQ
Default Setting: OFF
OFF:
BAND: When you change bands on the Main (VFO-
FREQ: This function is the almost same as "BAND,"
040. TIME OUT TIMER
Function: Sets the Time-Out Timer countdown time.
Available Values: OFF/5/10/15/20/25/30 min
Default Setting: OFF
The Time-Out Timer shuts off the transmitter after
continuous transmission of the programmed time.
041. TRV OFFSET
Function: Set the 10's and 1's of the MHz digits dis-
play for operation with a transverter.
Available Values: 30 ~ 49 MHz
Default Setting: 44 MHz
If you connect a 430 MHz transverter to the radio, set
this menu to "30" (the "100 MHz" digits are hidden on
this radio).
042. μTUNE DIAL STEP
Function: Select the μ-TUNE mode.
Available Values: DIAL STEP-1/DIAL STEP-2/OFF
Default Setting: DIAL STEP-1
DIAL STEP-1: Activates the μ-TUNE system in the
DIAL STEP-2: Activates the μ-TUNE system in the
OFF:
Advice: If none of the RF μ-Tuning Unist is installed,
changing this Menu setting will have no effect.
Disables the VFO Tracking feature.
A) side, the Sub (VFO-B) band's VFO will
automatically change to be the same as that
of VFO-A.
however, furthermore, the Sub band's (VFO-
B) frequency changes together with the Main
band's (VFO-A) frequency when turning the
Main Dial Tuning knob.
Auto mode using "FINE" steps of the
[ μ-TUNE ] knob (1 step/click) on the
14 MHz and lower amateur bands on
the Main band (VFO-A).
Auto mode using "COARSE" steps of
the [ μ-TUNE ] knob (2 steps/click) on
the 7 MHz and lower amateur bands.
On the 10/14 MHz bands,"FINE" μ-TUNE
knob steps will be used (1 step/click).
Disables the μ-TUNE system. Acti-
vates the VRF feature on the 14 MHz
and lower amateur bands on the Main
band (VFO-A).
FT
9000MP O
DX
PERATION
M
ANUAL

Advertisement

Table of Contents
loading

Table of Contents