If Noise Blanke (Nb) Operation - Yaesu FTDX9000MP Operation Manual

Hide thumbs Also See for FTDX9000MP:
Table of Contents

Advertisement

The FT
9000MP includes an effective IF Noise Blanker, which can significantly reduce noise caused by automotive
DX
ignition systems.
SUB(VFO-B) [NB] Knob
( VFO-A ) NB O
M
B
AIN
AND
1. Press the VFO-A [ NB ] switch momentarily to reduce
a short pulse noise such as from switching transients,
automobile ignitions and power lines. The LED im-
bedded in the switch will glow Red to confirm that
the Narrow-NB is operating.
Press and hold the VFO-A [ NB ] switch for two sec-
onds to reduce a longer duration man-made pulse
noise. The LED imbedded in the switch will glow
Yellow to confirm that the Wide-NB is operating.
2. Advance the VFO-A [ NB ] control to the point where
the offending ignition noise is best reduced or elimi-
nated.
To end Noise Blanker operation, press the VFO-A [ NB ]
switch once more. The LED imbedded in the switch will
turn off, confirming that the Noise Blanker is no longer in
operation.
FT
9000MP O
DX
PERATION
I I I I I
NTERFERENCE
NTERFERENCE
NTERFERENCE
NTERFERENCE
NTERFERENCE
IF N
B
OISE
LANKER
MAIN(VFO-A) [NB] Knob
MAIN(VFO-A) [NB] Switch
SUB(VFO-B) [NB] Switch
PERATION
M
ANUAL
R R R R R
EJECTION
EJECTION
EJECTION
EJECTION
EJECTION
( NB ) O
PERATION
( VFO-B ) NB O
S
B
UB
AND
1. Pressing the Sub (VFO-B) band's [ RX ] switch will
engage Dual Receive operation.
When the imbedded LED grows green, this is your
confirmation that Dual Receive is in operation.
2. Press the VFO-B [ NB ] switch momentarily to reduce
a short pulse noise such as from switching transients,
automobile ignitions and power lines. The LED im-
bedded in the switch will glow Umber to confirm that
the Narrow-NB is operating.
Press and hold the VFO-B [ NB ] switch for two sec-
onds to reduce a longer duration man-made pulse
noise. The LED imbedded in the switch will glow Yel-
low to confirm that the Wide-NB is operating.
3. Advance the VFO-B [ NB ] control to the point where
the offending ignition noise is best reduced or elimi-
nated.
To end Noise Blanker operation, press the VFO-B [ NB ]
switch once more. The LED imbedded in the switch will
turn off, confirming that the Noise Blanker is no longer in
operation.
A A A A A
D D D D D VICE
When the Roofing filter mode is set to "AUTO"
and the Noise Blanker is turned On, the Roofing
Filter bandwidth will automatically be set to 15 kHz.
(S (S (S (S (S
3 3 3 3 3
IGN
IGNALS
IGN
ALS WITHIN
ALS
ALS
WITHIN
WITHIN
WITHIN
KHZ
KHZ
KHZ
IGN
IGN
ALS
WITHIN
KHZ
KHZ
VDD
BIAS
TEMP
SWR
PERATION
VICE
VICE
VICE
VICE
Page 79
) ) ) ) )

Advertisement

Table of Contents
loading

Table of Contents