Yaesu FTDX9000MP Operation Manual page 161

Hide thumbs Also See for FTDX9000MP:
Table of Contents

Advertisement

114. MAIN FIX 1.8 MHz
Function: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the Main
band (VFO-A) 160 m amateur band.
Available Values: 1800 - 1999 kHz (1 kHz steps)
Default Setting: 1800 kHz
115. MAIN FIX 3.5 MHz
Function: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the Main
band (VFO-A) 80 m amateur band.
Available Values: 3500 - 3999 kHz (1 kHz steps)
Default Setting: 3500 kHz
116. MAIN FIX 5.0 MHz
Function: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the Main
band (VFO-A) 60 m amateur band.
Available Values: 5250 - 5499 kHz (1 kHz steps)
Default Setting: 5250 kHz
117. MAIN FIX 7.0 MHz
Function: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the Main
band (VFO-A) 40 m amateur band.
Available Values: 7000 - 7299 kHz (1 kHz steps)
Default Setting: 7000 kHz
118. MAIN FIX 10 MHz
Function: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the Main
band (VFO-A) 30 m amateur band.
Available Values: 10100 - 10149 kHz (1 kHz steps)
Default Setting: 10100 kHz
119. MAIN FIX 14 MHz
Function: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the Main
band (VFO-A) 20 m amateur band.
Available Values: 14000 - 14349 kHz (1 kHz steps)
Default Setting: 14000 kHz
120. MAIN FIX 18 MHz
Function: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the Main
band (VFO-A) 17 m amateur band.
Available Values: 18000 - 18199 kHz (1 kHz steps)
Default Setting: 18068 kHz
121. MAIN FIX 21 MHz
Function: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the Main
band (VFO-A) 15 m amateur band.
Available Values: 21000 - 21449 kHz (1 kHz steps)
Default Setting: 21000 kHz
FT
9000MP O
DX
PERATION
SCOPE G
M
ANUAL
ROUP
122. MAIN FIX 24 MHz
Function: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the Main
band (VFO-A) 12 m amateur band.
Available Values: 24800 - 24989 kHz (1 kHz steps)
Default Setting: 24890 kHz
123. MAIN FIX 28 MHz
Function: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the Main
band (VFO-A) 10 m amateur band.
Available Values: 28000 - 29699 kHz (1 kHz steps)
Default Setting: 28000 kHz
124. MAIN FIX 50 MHz
Function: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the Main
band (VFO-A) 6 m amateur band.
Available Values: 50000 - 53999 MHz (1 kHz steps)
Default Setting: 50000 kHz
125. SUB FIX 1.8 MHz
Function: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the Sub
band (VFO-B) 160 m amateur band.
Available Values: 1800 - 1999 kHz (1 kHz steps)
Default Setting: 1800 kHz
126. SUB FIX 3.5 MHz
Function: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the Sub
band (VFO-B) 80 m amateur band.
Available Values: 3500 - 3999 kHz (1 kHz steps)
Default Setting: 3500 kHz
127. SUB FIX 5.0 MHz
Function: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the Sub
band (VFO-B) 60 m amateur band.
Available Values: 5250 - 5499 kHz (1 kHz steps)
Default Setting: 5250 kHz
128. SUB FIX 7.0 MHz
Function: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the Sub
band (VFO-B) 40 m amateur band.
Available Values: 7000 - 7299 kHz (1 kHz steps)
Default Setting: 7000 kHz
129. SUB FIX 10 MHz
Function: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the Sub
band (VFO-B) 30 m amateur band.
Available Values: 10100 - 10149 kHz (1 kHz steps)
Default Setting: 10100 kHz
M M M M M
M M M M M
ENU
ENU
ENU
ODE
ODE
ODE
ENU
ENU
ODE
ODE
Page 159

Advertisement

Table of Contents
loading

Table of Contents