Slideout Room - Extreme Weather Precaution; Slideout Room Troubleshooting - Electric - Winnebago Chalet Manual

Hide thumbs Also See for Chalet:
Table of Contents

Advertisement

D-Series Class-A
Retract Procedure:
See "Before Retracting!" before proceeding.
Start the engine so the alternator can provide
maximum power for proper operation of
slideout mechanisms.
Press the Slideout Room 'RETRACT/IN'
switch and hold until the room is fully
retracted– then release the switch.
To stop retracting the room during operation,
release the button.
After the room has been retracted, refasten the
safety travel straps.
SLIDEOUT ROOM – EXTREME
WEATHER PRECAUTION
Certain extreme weather conditions, such as
heavy rains, heavy snow, and high winds – or any
combination of these – could cause damage to the
slideout room awning-cover (if equipped) or
reduce effectiveness of the slideout room weather
seals.
Also, freezing rain and snow can prevent the
slideout awning-cover (if equipped) from closing
and may cause damage to the awning-cover,
slideout room, weather seals and mechanisms.
To avoid potential damage, we recommend
retracting your slideout room(s) during extreme
weather conditions.
SLIDEOUT ROOM
TROUBLESHOOTING –
ELECTRIC
Battery Voltage or Circuit Breaker
Problems
If the slideout room will not work:
Τhe chassis battery may be low on charge.
Press and hold the Battery Boost switch on the
dash while pressing the slideout control
switch. This momentarily connects the house
batteries to assist in retracting the room.
SLIDEOUT / LEVELING
The circuit breaker may be tripped. The
circuit breaker, labeled 'Slideout Power' is
located on a panel on an interior wall of the
passenger side storage compartment just
behind or ahead of the entrance door.
Problems Retracting the Room
Set the Park Brake if the red Park Brake light
flashes while pressing the Retract button.
Green light will flash error code
if system malfunctions*
Diagnostics
Reset Button*
*Not equipped on single mechanism systems
If an error is detected on your DigiSync Room
Slide System, the green LED on the left side of
the control panel will blink an error code. If an
error code appears, see the On Board diagnostics
section to determine the problem. The error code
must be cleared prior to operating the room. To
clear the error, press the "RESET" button with a
small tool such as a toothpick. Before operating
the room after an error has been detected, check
for obvious faults such as obstructions prior to
trying to operate the room again. If the error code
appears again, the room will need to be retracted
using either the manual retraction method or the
fully manual method. Both methods listed below
are intended as a means to retract the room to
prepare the coach for travel to the nearest
authorized Service Center.
To retract the room after an error is detected,
you override the synchronization programming
and operate the room in the Manual Mode.
SECTION 10
Red light will flash if
park brake not set.
10-3