Winnebago Chalet Manual page 90

Hide thumbs Also See for Chalet:
Table of Contents

Advertisement

SECTION 10
SLIDEOUT / LEVELING
Manual Mode:
Manual Mode lets you individually move the
two room arms by pressing the IN and OUT
buttons on the control pad. This mode can be used
only if there is not a motor failure or full
electrical system failure. To override the encoder
and enter the Manual Mode, press and hold the
RESET button until the two LEDs begin to flash.
While in the Manual Mode each of the two,
room slide arms are activated by pressing and
holding the IN and OUT buttons. The "OUT"
button will retract the front arm. The "IN" button
will retract the back arm. Both IN and OUT
buttons may be held down at the same time to
simultaneously activate both arms to retract the
room. If one side of the room gets ahead of the
other, release that button until the other arm
catches up. The current limiting feature of the
control still functions in the Manual Mode so
each side can be fully retracted until it stops.
CAUTION
Never let one side get more than 2 inches
(50 mm) ahead of the other while
retracting.
Once the room has been retracted, the control
will return to the automatic mode after 60
seconds. You can manually return to automatic
mode by pressing the stop button.
In the event of a total system failure where
Manual Mode cannot be used, two crank handles
may be used to retract or extend the room.
Problems Extending the Room
Set the Park Brake if the red Park Brake light
flashes while pressing the Extend button.
10-4
Green light will flash error code,
if system malfunctions
Diagnostics
Reset Button
If an error is detected, the green LED on the
left side of the control panel will blink an error
code. If an error code appears, see the Error
Codes chart in your InfoCase. The error code
must be cleared prior to operating the room. To
clear the error, press the "RESET" button with a
small tool such as a toothpick. Before operating
the room after an error has been detected, check
for obvious faults such as obstructions before
trying to operate the room again. If the error code
appears again, the room will need to be extended
using the crank method described in the previous
section. The crank method is provided as a means
to extend the room if there is a failure in the
automatic system. If the room must be extended
using the crank method, keep in mind it is likely
that it must also be cranked in to retract. After the
outing is completed and the room is retracted
fully, take the coach to the nearest authorized
service center for inspection.
Further Information
See the Slideout Room operating guide
included in your InfoCase for further
instructions, and troubleshooting information.
D-Series Class-A
Red light will flash
if park brake not set.

Advertisement

Table of Contents
loading