120-Volt Receptacles (Outlets); Ground Fault Circuit Interrupter - Winnebago Chalet Manual

Hide thumbs Also See for Chalet:
Table of Contents

Advertisement

SECTION 6
ELECTRICAL
Shut off the equipment (example: roof air
conditioner) and allow a brief cooling period.
Then reset the breaker by moving the switch to
"Off" and back to "On". If the breaker is
continually tripped and no overload is evident,
have the system checked for a short in the wiring
or the appliances.
The breaker panels are located behind a door
or pull-off panel on a lower cabinet face in either
the galley or lounge area or beneath the rear bed.
Typical view of breaker panel. Breakers are
labeled on panel. Arrangement may vary
according to appliance and equipment options.
120-Volt House Circuit Breakers
120-VOLT RECEPTACLES
(OUTLETS)
A number of standard household electrical
outlets are provided throughout the coach for
connecting small appliances such as televisions,
radios, toasters, etc.
An exterior outlet is also located on the
outside of the coach near the entrance door or in
a storage compartment on the passenger side of
the coach.
6-4
GROUND FAULT CIRCUIT
INTERRUPTER
Bath, galley and exterior outlets are connected
to a GFCI (Ground Fault Circuit Interrupter),
which is an extremely sensitive circuit breaker
that will help to protect against severe electrical
shock if a ground fault develops. If such a
condition occurs, the GFCI will break the circuit
by turning off the power to the protected outlets.
Should this occur, unplug all the appliances on
that circuit and press the reset button on the GFCI
equipped outlet.
If the GFCI keeps tripping, have the electrical
system checked and repaired, if necessary, before
using again.
GFCI Outlet
(Ground Fault Protector)
WARNING
The GFCI will not completely eliminate
the risk of electrical shock. Small children
and persons with heart conditions or other
disabilities which make them especially
sensitive to electrical shock may still be
injured by a 120-volt receptacles even
though protected by a Ground Fault
Circuit Interrupter.
D-Series Class-A
Push to Reset
circuit after
monthly
testing or
ground fault
tripping.
Push to Test
at least
monthly.
Should break
circuit. Press
Reset button
to reconnect.