Firmware Update Notes
The BIOS and SP firmware are matched and, unless specified, should always be
■
updated in unison.
There are two types of SP firmware, ELOM (Embedded Lights Out Manager) and
■
ILOM (Integrated Lights Out Manager).
Before updating your server, you must know the type of firmware (ELOM or
■
ILOM) installed on the SP.
Do not update an ELOM-based SP using ILOM firmware. If you need to convert
■
an ELOM-based SP to an ILOM-based SP, use the ELOM-to-ILOM migration
process, which is described in the ELOM-to-ILOM Migration Guide.
Downgrading firmware is not recommended, because downgrading firmware
■
might eliminate important security and functionality updates.
Recovery procedures for failed updates are described in the product's Service
■
Manual.
Checking and Updating Your Firmware
1
2
3
4
5
6
7
10
Sun Fire X4450 Volume Configuration Guide • March 2009
Reboot the server and watch the screen for the prompt to press F2 to enter the
BIOS Setup Utility.
When the prompt appears, press F2. The BIOS Setup Utility main menu appears.
From the main menu, make note of the BIOS Version and the SP Firmware
Version
Exit the BIOS setup utility.
Access the Sun Fire X4450 server download site at:
http://www.sun.com/servers/x64/x4450/downloads.jsp
Compare the most recent BIOS and SP version numbers to the firmware versions
of the server.
If necessary, download the firmware and update the server using the ILOM.