Approved Vent; Vent Installation - Travis Industries GreenSmart 564 SS Installation Manual

Hide thumbs Also See for GreenSmart 564 SS:
Table of Contents

Advertisement

Approved Vent

Rear vent configurations use 8" diameter Simpson Dura-Vent Model Direct-Vent Pro (or GS).
Top vent configurations use 8" or 6-5/8" diameter Simpson Dura-Vent Direct-Vent Pro (or GS) vent. If
using 6-5/8" diameter vent, attach the 8" to 6-5/8" reducer (Travis part # 98900165) to the fireplace.
NOTE: When using 6-5/8" diameter vent, make sure to accommodate the 4" clearance above the
vent for the first 48" of rise (see vent clearances on page 22). Standard firestops do not include this
clearance.
Installation instructions for Simpson Dura-Vent may be found at www.duravent.com

Vent Installation

Slide the vent sections together and turn 1/4 turn until the sections lock in
place.
Screws are not required to secure the vent. However, three screws may be
used to secure vent sections together if desired.
High temperature sealant is recommended at the appliance starter section
connection (use high-temperature silicone or Mill-Pac®).
If disassembly is required, at time of re-assembly check to see if the vent
creates a tight fit. If it does not, apply high temperature sealant to the joints
of the affected sections.
Horizontal sections require a 1/4" rise every 12" of travel
Horizontal sections require non-combustible support every three feet (e.g.: plumbing tape)
© Travis Industries
Installation
(for qualified installers only)
6-5/8" Diameter Vent
Reducer - # 98900165
4081126
23
100-01210_000

Hide quick links:

Advertisement

Table of Contents
loading