Gas Line Location
Right Side Gas Inlet (preferred)
A 6" flex tube and shutoff valve is
included with the fireplace. The
shutoff valve accepts a 1/2"MPT.
Left Side Gas Inlet
A 3" high by 2" wide opening is located
behind the gas inlet cover plate. It is 4-3/4"
behind the front and 1-3/4" above the base
of the fireplace.
You may wish to route the flex line along
the front edge of the fireplace to conceal it.
You may remove this cover plate to
install the gas line. The cover plate has
a 7/8" diameter hole (covered with a
push plug). By rotating the plate 180
the hole may be re-located. You may
also secure the plate in a customized
location using the self-drilling screws.
© Travis Industries
Installation
(for qualified installers only)
A 3" high by 2" wide opening is located
behind the gas inlet cover plate. It is 7-3/4"
behind the front and 1-3/4" above the base
of the fireplace.
8-3/4"
13-3/4"
The gas inlet is located 2-1/2"
above the base of the fireplace.
You may remove this cover plate to install the gas line. The
cover plate has a 7/8" diameter hole (covered with a push
plug) in line with the gas inlet on the gas control valve. By
rotating the plate 180 the hole may be re-located. You may
also secure the plate in a customized location using the self-
drilling screws.
13-3/4"
4081126
A 6" flex tube and shutoff valve is
included with the fireplace (you may
wish to use a 24" flex tube). The
shutoff valve accepts a 1/2" MPT.
8-3/4"
100-01210_000
19