Troubleshooting - Piazzetta P960 Instructions For Installation, Use And Maintenance Manual

Table of Contents

Advertisement

8.0 TROUbLEShOOTING

a
Some of the problems indicated below may be resolved by following the instructions. All work must be carried out when the appliance
is cold and disconnected from the electricity supply (pull out the plug).
a
Authorised qualified persons must be contacted, in accordance with current regulations, whenever it is necessary to work on parts
inside the cladding or the firebox in order to resolve the problem.
It is therefore recommended that only your authorised service dealer be contacted.
Installation and repair sholud only be performed by a qualified service technician. Do not attempt to service the appliance yourself.
a
Unauthorised tampering with the appliance or the use of other than original spare parts not only creates situations of risk for operator
safety, but invalidates the warranty and relieves the manufacturer from all liability.
Problem
The control panel display is not lit
Stove combustion gas safety device
"ALF 1" stove status
58
Cause
The appliance is not powered
Faulty power cable
Fuses blown
Faulty control panel
Faulty flat cable
Faulty electronic board
Blocked flue or flue gas outlet
Fire door open
Fuel hopper lid remained opened for
more than 45 s
Broken smoke extractor
Flue system too long
Damaged door sealing gaskets
Hose connection blocked
Silicone piping blocked or broken
Faulty electronic board
H07028100/DT2000970 – 01
DT2011179-01
Solution
Check that the power cable is plugged
into the wall socket and connected to
the appliance
Replace the power cable (use only
original spares)
Check the fuses in both the plug and
the electronic board, replacing them if
necessary. If the problem persists call
an electrician
Replace the control panel (use only
original spares)
Replace the flat cable (use only
original spares)
Replace the electronic board (use only
original spares)
Check and clean the flue and the
outlet
Control if the door is closed
Control if the lid is closed
Replace the motor (use only original
spares)
Check correct installation
Check all the gaskets and seals of the
door and flue pipe
Dismantle and clean the hose
connection for the vacuum gauge
Check and/or replace piping
Replace the electronic board (use only
original spares)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

P961P962

Table of Contents